Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Example for Configuring CC Based on the Directly Connected Interface

Example for Configuring CC Based on the Directly Connected Interface

Networking Requirements

As networks develop quickly, IP networks carry multiple services such as voice and video services increasingly. The services pose high requirements on network reliability. Networks need to provide fast fault detection and processing.

In Figure 7-20, link connectivity needs to be detected.

Figure 7-20 Configuring CC based on the directly connected interface

Configuration Roadmap

The configuration roadmap is as follows:

  1. Configure CC on SwitchA and SwitchB to detect link connectivity.

  2. Configure association between CFM and an interface on SwitchA and configure SwitchA to make the associated interface to go Down when CFM detects a fault.

Procedure

  1. Configure CC.

    # Enable global CFM on SwitchA.

    <HUAWEI> system-view
    [~HUAWEI] sysname SwitchA
    [*HUAWEI] commit
    [~SwitchA] cfm enable
    Info: Succeeded in enabling CFM.
    [*SwitchA] commit

    # Enable global CFM on SwitchB.

    <HUAWEI> system-view
    [~HUAWEI] sysname SwitchB
    [*HUAWEI] commit
    [~SwitchB] cfm enable
    Info: Succeeded in enabling CFM.
    [*SwitchB] commit

    # Enable CC on SwitchA.

    [~SwitchA] cfm md md1
    [*SwitchA-md-md1] ma ma1
    [*SwitchA-md-md1-ma-ma1] mep mep-id 1 interface 10ge 1/0/1 outward
    [*SwitchA-md-md1-ma-ma1] mep ccm-send mep-id 1 enable
    [*SwitchA-md-md1-ma-ma1] remote-mep mep-id 2
    [*SwitchA-md-md1-ma-ma1] remote-mep ccm-receive mep-id 2 enable
    [*SwitchA-md-md1-ma-ma1] quit
    [*SwitchA-md-md1] quit
    [*SwitchA] commit

    # Enable CC on SwitchB.

    [~SwitchB] cfm md md1
    [*SwitchB-md-md1] ma ma1
    [*SwitchB-md-md1-ma-ma1] mep mep-id 2 interface 10ge 1/0/1 outward
    [*SwitchB-md-md1-ma-ma1] mep ccm-send mep-id 2 enable
    [*SwitchB-md-md1-ma-ma1] remote-mep mep-id 1
    [*SwitchB-md-md1-ma-ma1] remote-mep ccm-receive mep-id 1 enable
    [*SwitchB-md-md1-ma-ma1] quit
    [*SwitchB-md-md1] quit
    [*SwitchB] commit

    # Verify the configuration.

    After the configuration is complete, run the display cfm remote-mep command on SwitchA and SwitchB. You can see that the CFM status is up.

    [~SwitchA] display cfm remote-mep
    The total number of RMEPs is : 1                                                                                                    
    The status of RMEPs : 1 up, 0 down, 0 disable                                                                                       
    --------------------------------------------------                                                                                  
     MD Name            : md1                                                                                                           
     Level              : 0                                                                                                             
     MA Name            : ma1                                                                                                           
     RMEP ID            : 2                                                                                                             
     VLAN ID            : --                                                                                                            
     MAC                : 200b-c739-1301                                                                                                
     CCM Receive        : enabled                                                                                                       
     Trigger-If-Down    : disabled                                                                                                      
     Trigger-If-Link    : disabled                                                                                                      
     CFM Status         : up                                                                                                            
     Alarm Status       : none                    
    [~SwitchB] display cfm remote-mep
    The total number of RMEPs is : 1                                                                                                    
    The status of RMEPs : 1 up, 0 down, 0 disable                                                                                       
    --------------------------------------------------                                                                                  
     MD Name            : md1                                                                                                           
     Level              : 0                                                                                                             
     MA Name            : ma1                                                                                                           
     RMEP ID            : 1                                                                                                             
     VLAN ID            : --                                                                                                            
     MAC                : 749d-8f4c-dad1                                                                                                
     CCM Receive        : enabled                                                                                                       
     Trigger-If-Down    : disabled                                                                                                      
     Trigger-If-Link    : disabled                                                                                                      
     CFM Status         : up                                                                                                            
     Alarm Status       : none                    

  2. Configure association between CFM and an interface on SwitchA and configure SwitchA to make the associated interface to go Down when CFM detects a fault.

    # Configure association between CFM and an interface on SwitchA.

    [~SwitchA] interface 10ge 1/0/1
    [~SwitchA-10GE1/0/1] cfm md md1 ma ma1 remote-mep mep-id 2 trigger if-link-down
    [*SwitchA-10GE1/0/1] quit
    [*SwitchA] commit

    # Verify the configuration.

    After the configuration is complete, run the display cfm remote-mep command on SwitchA. You can see that the value of Trigger-If-Link is enabled.

    [~SwitchA] display cfm remote-mep
    The total number of RMEPs is : 1                                                                                                    
    The status of RMEPs : 1 up, 0 down, 0 disable                                                                                       
    --------------------------------------------------                                                                                  
     MD Name            : md1                                                                                                           
     Level              : 0                                                                                                             
     MA Name            : ma1                                                                                                           
     RMEP ID            : 2                                                                                                             
     VLAN ID            : --                                                                                                            
     MAC                : 200b-c739-1301                                                                                                
     CCM Receive        : enabled                                                                                                       
     Trigger-If-Down    : disabled                                                                                                      
     Trigger-If-Link    : enabled                                                                                                      
     CFM Status         : up                                                                                                            
     Alarm Status       : none                    

    After the configuration is complete, run the undo cfm enable command on SwitchB to simulate a link fault so that the remote device cannot receive CFM packets.

    [~SwitchB] undo cfm enable
    Warning: All information about the MD will be deleted if CFM is disabled. Continue? [Y/N]:y                                         
    Info: Succeeded in disabling CFM.
    [*SwitchB] commit

    You can see that the value of Line protocol current state is DOWN (CFM down) on 10GE1/0/1 of SwitchA.

    [~SwitchA] display interface 10ge 1/0/1
    10GE1/0/1 current state : UP (ifindex: 276)                                                                                        
    Line protocol current state : DOWN (CFM down) 
    ...
    NOTE:

    The key information of the display interface 10ge 1/0/1 command output is displayed here, and "..." indicates that some information is omitted.

    Reconfigure CC on SwitchB. You can see that the value of Line protocol current state is UP on 10GE1/0/1 of SwitchA.

    [~SwitchA] display interface 10ge 1/0/1
    10GE1/0/1 current state : UP (ifindex: 276)                                                                                        
    Line protocol current state : UP 
    ...
    NOTE:

    The key information of the display interface 10ge 1/0/1 command output is displayed here, and "..." indicates that some information is omitted.

Configuration Files

  • SwitchA configuration file

    #
    sysname SwitchA
    #
    cfm enable
    #
    interface 10GE1/0/1
     cfm md md1 ma ma1 remote-mep mep-id 2 trigger if-link-down
    #
    cfm md md1
     ma ma1
      mep mep-id 1 interface 10GE1/0/1 outward
      mep ccm-send mep-id 1 enable
      remote-mep mep-id 2
      remote-mep ccm-receive mep-id 2 enable
    #
    return
  • SwitchB configuration file

    #
    sysname SwitchB
    #
    cfm enable
    #
    cfm md md1
     ma ma1
      mep mep-id 2 interface 10GE1/0/1 outward
      mep ccm-send mep-id 2 enable
      remote-mep mep-id 1
      remote-mep ccm-receive mep-id 1 enable
    #
    return