Alarm Handling

AR100, AR120, AR160, AR1200, AR2200, AR3200, and AR3600 V300R003

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
LINE_1.3.6.1.4.1.2011.5.25.207.2.2 hwUserLogin

LINE_1.3.6.1.4.1.2011.5.25.207.2.2 hwUserLogin

Description

LINE/4/USERLOGIN:OID [oid] A user login. (UserIndex=[INTEGER], UserName=[STRING], UserIP=[STRING], UserChannel=[STRING])

This object indicates notification information about user login.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.207.2.2 Warning equipmentAlarm(5)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

UserIndex

Indicates the user index.

UserName

Indicates the user name.

When the device fails to obtain the user name, for example, in a password-based user authentication scenario, asterisks (**) are used to indicate the user name.

UserIP

Indicates the IP address of a user.

When the device fails to obtain the user IP address, for example, in a scenario where the user logs in using a Console interface or AUX interface, asterisks (**) are used to indicate the IP address.

UserChannel

Indicates the channel used by the user.

Impact on the System

This alarm message is informational only, and no action is required.

Possible Causes

When a user logs in to the device through Telnet, a notification is reported.

Procedure

  1. This alarm message is informational only, and no action is required.