Alarm Handling

AR100, AR120, AR160, AR1200, AR2200, AR3200, and AR3600 V300R003

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
HWCM_1.3.6.1.4.1.2011.6.10.2.1 hwCfgManEventlog

HWCM_1.3.6.1.4.1.2011.6.10.2.1 hwCfgManEventlog

Description

HWCM/4/CFGCHANGE:OID [oid] Configure changed. (EventIndex=[integer], CommandSource=[integer], ConfigSource=[integer], ConfigDestination=[integer])

The trap was generated when the configuration changed.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.6.10.2.1 Warning processingErrorAlarm(4)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

EventIndex

Indicates the index of EventTable.

CommandSource

Indicates a command source, that is, a command delivery mode that triggers changes.

  • 1. Command proxy
  • 2. Simple Network Management Protocol (SNMP)
  • 4. Others

ConfigSource

Configuration source, that is, the change source.

  • 1. Configuration file clearance
  • 2. Configuration file modification
  • 3. Tool-side configuration operation
  • 4. Saving of the next-startup configuration file
  • 5. Non-configuration file renaming or moving
  • 6. FTP-related get or put operation
  • 7. Hot swap of an interface board

ConfigDestination

Configuration destination, that is, the object to be changed.

  • 2. Running configurations
  • 4. Startup configuration file

Impact on the System

System will not be affected.

Possible Causes

Operations, such as copy, delete, rename, move, and download, were performed, causing the startup configuration file to be modified.

Procedure

  1. This alarm message is informational only, and no action is required.