AR100, AR120, AR160, AR1200, AR2200, AR3200, and AR3600 V300R003

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
RMON_1.3.6.1.2.1.16.0.1 risingAlarm

RMON_1.3.6.1.2.1.16.0.1 risingAlarm

Description

RMON/4/ALARMUP:OID [OID] Alarm table [alarm-table-index] monitors [sample-object-oid] with the sample type being [sample-type], and the sampled alarm value [alarm-value] is greater than or equal to [rising-value].

The value of the alarm entity was higher than uprise.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.2.1.16.0.1 Warning environmentalAlarm(6)

Parameters

Name Meaning

OID

Indicates the MIB object ID of the alarm.

alarm-table-index

Indicates the index of the alarm entry.

sample-object-oid

Indicates the OID of the sampled object.

sample-type

Indicates the type of the sampled alarm.

alarm value

Indicates the alarm value.

rising-value

Indicates the upper threshold of the alarm.

Impact on the System

None.

Possible Causes

Cause 1:

If the current sampled value was greater than or equal to this threshold, and the last sampled value was less than this threshold, the alarm was generated.

Cause 2:

When this alarm entry became valid, the first sampled value was greater than or equal to this threshold, and alarmStartupAlarm was equal to risingAlarm and risingOrFallingAlarm, the alarm was generated.

Procedure

  • This alarm is triggered only when the upper interface traffic monitoring threshold configured using the rmon alarm command is reached. It is a user-configured monitoring alarm and does not affect services. Therefore, no action is required.

Related Information

None.