No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

AR100, AR120, AR160, AR1200, AR2200, AR3200, and AR3600 V300R003

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
NETSTREAM_1.3.6.1.4.1.2011.5.25.110.2.0.3 hwNetStreamSessionFull

NETSTREAM_1.3.6.1.4.1.2011.5.25.110.2.0.3 hwNetStreamSessionFull

Description

NETSTREAM/4/SSNFULL: OID [oid] netstream session full trap.(TrafficType=[INTEGER])

This alarm is generated when the number of traffic entries in the NetStream table reaches the maximum number.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.110.2.0.3 Warning equipmentAlarm(5)

Parameters

Name Meaning
[TrafficType] Indicates traffic type, including:
  • 1: Original flow
  • 2: Aggregation flow

Impact on the System

The following packets are discarded and no NetStream analysis is performed.

Possible Causes

Causes:

  1. The number of traffic entries generated from the original flow exceeds 80% of the maximum number.
  2. The number of traffic entries generated from the aggregation flow exceeds 80% of the maximum number.

Procedure

  • This alarm is a common event during the NetStream operation and no action is required.

Related Information

None.