Alarm Handling

AR100, AR120, AR160, AR1200, AR2200, AR3200, and AR3600 V300R003

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
WLAN_1.3.6.1.4.1.2011.6.139.14.1.3 hwWlanApUpdateUbootNotMatchTrap

WLAN_1.3.6.1.4.1.2011.6.139.14.1.3 hwWlanApUpdateUbootNotMatchTrap

Description

WLAN/4/AP_UBOOT_NOT_MATCH_NOTIFY:OID [oid] AP uboot is not match AP version.(APMAC=[OPAQUE], APName=[STRING], APID=[INTEGER])

The AP began to upgrade.

Attribute

Alarm ID Alarm Severity Alarm Type

1.3.6.1.4.1.2011.6.139.14.1.3

Warning

processingErrorAlarm(4)

Parameters

Name Meaning
OID Indicates the ID of the MIB object.
APMac Indicates the MAC address of an AP.
APName Indicates the AP name.
APID Indicates the AP ID.

Impact on the System

The AP cannot work properly because of upgrade failures.

Possible Causes

The U-boot version does not match the AP version.

Procedure

  1. Contact the technical support personnel to obtain the AP version matches the U-boot version.
  2. Upgrade the AP according to the AC Upgrade Guide. Then, check whether the alarm persists.

    • If so, go to Step 3.
    • If not, go to Step 4.

  3. Collect alarm messages, log messages, and configurations, and then contact the technical support personnel.
  4. End.