Alarm Handling

AR100, AR120, AR160, AR1200, AR2200, AR3200, and AR3600 V300R003

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ARP_1.3.6.1.4.1.2011.5.25.123.2.32 hwEthernetARPEntryExceedAlarm

ARP_1.3.6.1.4.1.2011.5.25.123.2.32 hwEthernetARPEntryExceedAlarm

Description

ARP/2/ARP_SPECEXCEED_TRAP: OID [OID] The number of ARP entries reached the specs. (entPhysicalIndex=[INTEGER], Slot name=[OCTET], Specs=[COUNTER], Number of dynamic ARP entries=[COUNTER], Number of static ARP entries=[COUNTER]).

The number of ARP entries exceeded the specified threshold.

Attribute

Alarm ID Alarm Severity Alarm Type

1.3.6.1.4.1.2011.5.25.123.2.32

Major

qualityOfServiceAlarm

Parameters

Name Meaning

OID

Indicates the MIB object ID of the alarm.

entPhysicalIndex

Physical entity index

Slot name

Board name

Specs

Maximum number of ARP entries

Number of dynamic ARP entries

Number of dynamic ARP entries

Number of static ARP entries

Number of static ARP entries

Impact on the System

New ARP entries fail to be learned, causing service interruptions.

Possible Causes

The number of ARP entries learned on the device exceeded the specified threshold.

Procedure

  1. Run the display arp statistics command to view statistics about ARP entries on the device. Check whether the number of static ARP entries is greater than the number of dynamic ARP entries or vice versa based on the network planning and service deployment.

    • If the number of dynamic ARP entries is greater than the number of static ARP entries, go to Step 2.
    • If the number of static ARP entries is greater than the number of dynamic ARP entries, go to Step 3.

  2. Run the command to determine the interfaces that have a large number of ARP entries. On these interfaces, run the display arp interface command to check whether the ARP entries are required by users.

    • If the ARP entries are required by users, go to Step 5.
    • If the ARP entries are not required by users, run the reset arp command to delete these ARP entries and then go to Step 4.

  3. Run the display current-configuration command to check whether the static ARP entries are required by users.

    • If the static ARP entries are required by users, go to Step 5.
    • If the static ARP entries are not required by users, given that services are not affected, run the undo arp static command and delete specified static ARP entries or run the reset arp static command to delete all static ARP entries. Then, go to Step 4.

  4. Run the display arp statistics command to check whether the total number of ARP entries on the device is increasing unexpectedly.

    • If the total number of ARP entries is not increasing, go to Step 6.
    • If the total number of ARP entries is still increasing, go to Step 5.

  5. Collect alarm information and configuration information, and then contact technical support personnel.
  6. End.