No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

AR100, AR120, AR160, AR1200, AR2200, AR3200, and AR3600 V300R003

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
AMPADP_1.3.6.1.4.1.2011.5.104.1.0.7 hwGponnniOntLinkSufFailAlarmTrap

AMPADP_1.3.6.1.4.1.2011.5.104.1.0.7 hwGponnniOntLinkSufFailAlarmTrap

Description

AMPADP/2/ONT_SUF: OID [oid] The ranging of the ONT failure occurs.

This alarm is reported if ranging fails on an ONT.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.104.1.0.7 Warning environmentalAlarm(6)

Parameters

Name Meaning

oid

OID of the alarm MIB object.

Impact on the System

Under the current port, the ONT where ranging fails cannot properly work.

Possible Causes

  • Cause 1: The quality of the optical path is poor.

  • Cause 2: A hardware fault occurs on the ONT.

Procedure

  1. Check the optical fiber.

    • If the optical fiber is loose or disconnected, reconnect the optical fiber to ensure that the optical fiber is connected correctly and securely.
    • If the optical fiber is aged out, bent, or damaged, replace the optical fiber.
    • If the optical fiber connector is dirty, clean it.

    After any of the preceding operations, check whether the alarm is cleared.

    • If so, go to step 4.

    • If not, go to step 2.

  2. Reset or replace the ONT, and check whether the alarm is cleared.

    • If so, go to step 4.

    • If not, go to step 3.

  3. Collect alarm and configuration information, and contact technical support personnel.
  4. End.
Translation