Alarm Handling

AR100, AR120, AR160, AR1200, AR2200, AR3200, and AR3600 V300R003

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
L2V_1.3.6.1.4.1.2011.5.25.119.4.1.2.10 hwVpwsPwRedundancyDegraded

L2V_1.3.6.1.4.1.2011.5.25.119.4.1.2.10 hwVpwsPwRedundancyDegraded

Description

L2V/2/PWE3_VPWS_DEGRADED_T: OID [OID] VPWS PW redundancy reported a protect degraded alarm. (PrimaryPwId=[GAUGE], PrimaryPwType=[INTEGER], InterfaceIndex=[INTEGER], InterfaceName=[STRING])

VPWS PW redundancy, VLL FRR, or PW-APS protection degraded.

Attribute

Alarm ID Alarm Severity Alarm Type

1.3.6.1.4.1.2011.5.25.119.4.1.2.10

Major

qualityOfServiceAlarm(3)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

PrimaryPwId

Primary PW ID

PrimaryPwType

Primary PW type

InterfaceIndex

Index of the interface where the PW resides

InterfaceName

Interface where the PW resides

Impact on the System

If the primary or secondary PW for VPWS PW redundancy fails, VPWS PW redundancy protection will degrade.

If the primary or secondary PW for VLL FRR fails, VLL FRR protection will degrade.

If the primary or secondary PW for PW-APS fails, PW-APS protection will degrade.

Possible Causes

The primary or secondary PW for VPWS PW redundancy failed.

The primary or secondary PW for VLL FRR failed.

The primary or secondary PW for PW-APS failed.

Procedure

  1. Perform the troubleshooting operations described in hwPWVcDown to rectify the fault and then check whether the trap is cleared.

    • If trap is cleared, go to step 2.
    • If trap is not cleared, go to step 3.

  2. Collect alarm information and configuration information, and then contact technical support personnel.
  3. End.