Alarm Handling

AR100, AR120, AR160, AR1200, AR2200, AR3200, and AR3600 V300R003

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
NQA_1.3.6.1.4.1.2011.5.25.111.6.4 nqaResultsThresholdNotification

NQA_1.3.6.1.4.1.2011.5.25.111.6.4 nqaResultsThresholdNotification

Description

NQA/4/THRESHOLD:OID [oid] NQA entry over threshold. (OwnerIndex=[OCTET], TestName=[OCTET])

Indicates that the period of a test exceeded the set threshold. The threshold could be set by the user. The threshold rtd could modify the threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.111.6.4 Warning processingErrorAlarm(6)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

OwnerIndex

Indicates the administrator of an NQA test instance.

TestName

Indicates the name of an NQA test instance.

Impact on the System

None.

Possible Causes

This trap occurs in the NQA test.

1.

The threshold was set too small.

2.

The network was busy.

Procedure

  1. Run the display cpu-usage command in the system view to check whether the CPU has an excessive usage.

    • If so, go to Step 3.
    • If not, go to Step 2.

  2. In the NQA test view, run the display this command to know the current threshold. Then run the threshold rtd command to modify the threshold as required. The recommended value is 20 ms.

    Perform the test again to check whether the alarm is cleared.
    • If so, go to Step 4.
    • If not, go to Step 3.

  3. Collect alarm information and configuration information, and then contact technical support personnel.
  4. End.