Alarm Handling

AR100, AR120, AR160, AR1200, AR2200, AR3200, and AR3600 V300R003

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
SSMPADP_1.3.6.1.6.3.1.1.5.5_authenticationFailure

SSMPADP_1.3.6.1.6.3.1.1.5.5_authenticationFailure

Description

SSMPADP/4/AUTHENTICAL_FAIL:OID [oid] SNMP authentication fails.

SNMP authentication fails.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.6.3.1.1.5.5 Warning other(1)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

Impact on the System

None

Possible Causes

Cause 1: An incorrect community name is used to connect to the device.

Cause 2: An incorrect SNMPv3 user name is used to connect to the device.

Procedure

  1. Run the display current-configuration command in the user view to check whether the community name or SNMPv3 user name is correctly configured.

    • If so, go to step 3.
    • If not, go to step 2.

  2. Run the snmp-agent community command in the system view to modify the community name, run the snmp-agent usm-user command in the system view to create a correct user, and check whether the alarm is cleared.

    • If so, go to step 4.
    • If not, go to step 3.

  3. Collect alarm, log, and configuration information, and contact technical support personnel.
  4. End.