Alarm Handling

AR100, AR120, AR160, AR1200, AR2200, AR3200, and AR3600 V300R003

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
FIB_1.3.6.1.4.1.2011.5.25.129.2.9.6 hwFESInconsistencyForMemoryLackResume

FIB_1.3.6.1.4.1.2011.5.25.129.2.9.6 hwFESInconsistencyForMemoryLackResume

Description

FIB/1/INCONSISFORMEMLACKRESUME: OID [oid] The memory usage of the interface board reduces to the lower threshold, and the FES can add entries. The entries of the interface board is consistent with those of the main board. (EntityPhysicalIndex=[INTEGER], HwBaseTrapSeverity=[INTEGER], HwBaseTrapEventType=[INTEGER], EntPhysicalName=[STRING])

The memory usage of the interface board fell below the upper threshold, and the FES could add entries. The entries of the interface board and main control board were consistent.

Attribute

Alarm ID Alarm Severity Alarm Type

1.3.6.1.4.1.2011.5.25.129.2.9.6

Critical

equipmentAlarm(5)

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
EntityPhysicalIndex Physical entity index
HwBaseTrapSeverity Trap severity
HwBaseTrapEventType Trap type
EntPhysicalName Physical entity name

Impact on the System

Routing entries, MPLS entries, and L2VPN entries are added to the interface board, and the entries of the interface board and main control board are consistent.

Possible Causes

The memory usage of the interface board fell below the upper threshold.

Procedure

  1. This alarm message is informational only, and no action is required.