Alarm Handling

AR100, AR120, AR160, AR1200, AR2200, AR3200, and AR3600 V300R003

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
AAA_1.3.6.1.4.1.2011.5.2.2.2.0.106 hwNACUserClearAlarm

AAA_1.3.6.1.4.1.2011.5.2.2.2.0.106 hwNACUserClearAlarm

Description

AAA/4/NACUserClearAlarm: OID [OID] The NAC Max User Alarm is cleared.(Slot:[OCTET] User-num:[INTEGER] Threshold:[INTEGER]%)

The percentage of successfully authenticated NAC users reached or fell below the lower alarm threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.2.2.2.0.106 Warning qualityOfServiceAlarm(3)

Parameters

Name Meaning
[OID] Indicates the MIB object ID of the alarm.
Slot:[OCTET] Indicates a slot ID.
User-num:[INTEGER] Indicates the number of successfully authenticated NAC users.
Threshold:[INTEGER]% Indicates the percentage of successfully authenticated NAC users.

Impact on the System

This is the clear alarm for the alarm generated when the percentage of successfully authenticated NAC users reaches the upper alarm threshold.

Possible Causes

The percentage of successfully authenticated NAC users reached or fell below the lower alarm threshold.

Procedure

  • This alarm is informational only, and no action is required.