No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

AR100, AR120, AR160, AR1200, AR2200, AR3200, and AR3600 V300R003

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
GRE_1.3.6.1.4.1.2011.5.25.201.3.4 hwHybridTunnelCreateFail

GRE_1.3.6.1.4.1.2011.5.25.201.3.4 hwHybridTunnelCreateFail

Description

GRE/4/BONDING_CREATEFAIL:OID [oid] The tunnel fails to be created.(Interface=[Interface], TunnelType=[TunnelType], CreateFailValue=[CreateFailValue])

The hybrid bonding tunnel failed to be created.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.201.3.4 Warning other

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
Interface Index of the interface
TunnelType
Tunnel type:
  • 0: priority tunnel

  • 1: overflow tunnel

CreateFailValue Error code for the tunnel creation failure

Impact on the System

Traffic to be forwarded through the hybrid bonding tunnel is interrupted.

Possible Causes

Cause 1: The source IP address of the tunnel interface on the CPE has been used for tunnel establishment on the router.

Cause 2: The router prohibits the client from creating a tunnel.

Procedure

  1. Check the error code specified by the CreateFailValue field in the trap information, and perform the corresponding action based on the error code.

    • If the error code is 404, the source IP address of the tunnel interface on the CPE has been used for tunnel establishment on the router. Go to Step 2.

    • If the error code is 405, the router prohibits the client from creating a tunnel. Go to Step 3.

  2. Obtain the tunnel interface configurations on the CPE and router, and check whether the same source IP address has been configured using the source command.

    • If the same source IP address has been configured, go to Step 4.

    • If the same source IP address has not been configured, go to Step 6.

  3. Check whether the cin filter deny command has been run on the router to prohibit the client from creating a tunnel.

    • If the cin filter deny command has been run on the router, go to Step 5.

    • If the cin filter deny command has not been run on the router, go to Step 6.

  4. Run the source command in the tunnel interface view on the CPE to change the source IP address. Then check whether the tunnel is successfully established.

    • If the tunnel is successfully established, go to Step 7.

    • If the tunnel fails to be established, go to Step 6.

  5. Run the cin filter permit command on the router to allow the client to create a tunnel. Then check whether the tunnel is successfully established.

    • If the tunnel is successfully established, go to Step 7.

    • If the tunnel fails to be established, go to Step 6.

  6. Collect alarm information and configuration information, and then contact technical support personnel.
  7. End.