Alarm Handling

AR100, AR120, AR160, AR1200, AR2200, AR3200, and AR3600 V300R003

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
FIB_1.3.6.1.4.1.2011.5.25.129.2.9.5 hwFESInconsistencyForMemoryLack

FIB_1.3.6.1.4.1.2011.5.25.129.2.9.5 hwFESInconsistencyForMemoryLack

Description

FIB/1/INCONSISFORMEMLACK: OID [oid] Because the memory usage of the interface board exceeds the upper threshold, the FES cannot add new entries. As a result, the entries of the interface board is inconsistent with those of the main board. (EntityPhysicalIndex=[INTEGER], HwBaseTrapSeverity=[INTEGER], HwBaseTrapEventType=[INTEGER], EntPhysicalName=[STRING])

Because the memory usage of the interface board exceeded the upper threshold, the FES could not add new entries. As a result, the entries of the interface board and main control board were inconsistent.

Attribute

Alarm ID Alarm Severity Alarm Type

1.3.6.1.4.1.2011.5.25.129.2.9.5

Critical processingErrorAlarm(4)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

EntityPhysicalIndex

Physical entity index

HwBaseTrapSeverity

Trap severity

HwBaseTrapEventType

Trap type

EntPhysicalName

Physical entity name

Impact on the System

No new routing entries, MPLS entries, and L2VPN entries are added to the interface board. As a result, the entries of the interface board and main control board are inconsistent.

Possible Causes

The memory usage of the interface board exceeded the configured upper threshold.

Procedure

  1. Reduce services so that the memory usage of the interface board falls below the upper threshold.
  2. Run the display alarm active command to view the trap. Check whether the trap is cleared.