Alarm Handling

AR100, AR120, AR160, AR1200, AR2200, AR3200, and AR3600 V300R003

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
FR_1.3.6.1.2.1.10.32.0.1 frDLCIStatusChange

FR_1.3.6.1.2.1.10.32.0.1 frDLCIStatusChange

Description

FR/4/TRAP:OID [oid] Interface [interface-index] DLCI [dlci] turns into [state] state (invalid(1), active(2), inactive(3)).

The trap was generated when the PVC status changed. You can run the display fr pvc-info command to view the current PVC status.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.2.1.10.32.0.1 Warning qualityOfServiceAlarm(3)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

interface-index

Indicates the index of the interface.

dlci

Indicates the number of the Data Link Connection Identifier (DLCI). It ranges from 16 to 1022.

state

Indicates the number of the state. The mapping is as follows:
  • 1: invalid
  • 2: active
  • 3: inactive

Impact on the System

If the PVC status becomes inactive, the PVC is unavailable and then the mapping entries of the PVC are deleted. Finally, traffic cannot be normally forwarded.

If the PVC status becomes active, the PVC is available.

Possible Causes

The reasons of the PVC status became inactive are as follows:

1.

The interface configured with the PVC was shut down.

2.

The interface configured with the PVC failed to negotiate with the peer.

The reason of the PVC status became active is as follow:

The interface configured with this PVC succeeded in negotiating with the peer.

Procedure

  1. Run the display fr pvc-info command to check the PVC status.

    • If the PVC status is active, it indicates that the PVC is available. Then, go to Step 8.

    • If the PVC status is inactive, you can run the display fr pvc-info command to view the interface where the PVC resides. Then, go to Step 2.

  2. Run the display interface command to view the physical status of the interface.

    • If the interface is administratively Down, go to Step 3.

    • If the interface is Up, go to Step 4.

  3. Run the undo shutdown command in the interface view. Then, run the display fr pvc-info command to check whether the PVC status becomes active.

    • If so, go to Step 8.

    • If not, go to Step 4.

  4. Run the display interface command to check whether the protocol status of the interface is Up.

    • If so, go to Step 7.

    • If not, go to Step 5.

  5. Run the display this command in the interface view to check whether FR configurations are correct. For details, refer to "FR Configuration" in the Huawei AR100&AR120&AR150&AR160&AR200&AR1200&AR2200&AR3200&AR3600 Series Enterprise Routers Configuration Guide - WAN Access.

    • If so, go to Step 7.

    • If not, go to Step 6.

  6. Modify FR configurations on the interfaces on both ends of the PVC to be consistent. After 30 seconds, run the display fr pvc-info command to check whether the PVC status becomes active.

    • If so, go to Step 8.

    • If not, go to Step 7.

  7. Collect alarm information and configuration information, and then contact technical support personnel.
  8. End.