No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

AR100, AR120, AR160, AR1200, AR2200, AR3200, and AR3600 V300R003

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
BULKSTAT_1.3.6.1.4.1.2011.5.25.140.2.1 hwBulkStatCollectIncomplete

BULKSTAT_1.3.6.1.4.1.2011.5.25.140.2.1 hwBulkStatCollectIncomplete

Description

BULKSTAT/3/COLLECT_INCOMPLETE:OID [oid] The file collection is incomplete during the collection period. (FileIndex=[integer], FileName=[octet])

Collecting statistics on all statistics objects was not complete within a collection interval. The data collection in the last collection interval is complete. If the collection interval is the first one, the trap is directly generated.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.140.2.1 Minor processingErrorAlarm(4)

Parameters

Name Meaning

oid

Indicates the MIB object ID of the alarm.

FileIndex

indicates the index of a file.

filename

indicates the name of a file.

Impact on the System

Data collected in a collection cycle is incomplete, and thus the FTP server loses the data in an uploading cycle.

Possible Causes

1:

The CPU usage of the system was high.

2:

The number of sampling objects that were configured was beyond the sampling capability of the system.

Procedure

  1. Collect alarm information and configuration information, and then contact technical support personnel.
Translation
Download
Updated: 2019-03-06

Document ID: EDOC1100041475

Views: 70445

Downloads: 45

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next