No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Alarm Handling

AR100, AR120, AR160, AR1200, AR2200, AR3200, and AR3600 V300R003

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback :
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.4.5 hwOpticalInvalid 136199

ENTITYTRAP_1.3.6.1.4.1.2011.5.25.219.2.4.5 hwOpticalInvalid 136199

Description

ENTITYTRAP/4/OPTICALINVALID:OID [oid] Optical module is invalid.(Index=[INTEGER], EntityPhysicalIndex=[INTEGER], PhysicalName="[OCTET]", EntityTrapFaultID=136199, EntityTrapReasonDescr="Optical Current Too High")

The bias current of the optical module exceeds the upper limit.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.219.2.4.5 Warning equipmentAlarm(5)

Parameters

Name Meaning
oid

Indicates the MIB object ID of the alarm.

Index Indicates the index of the alarm.
EntityPhysicalIndex Indicates the entity index.
PhysicalName Indicates the name of the physical entity.
EntityTrapFaultID Indicates the error code of the alarm.
EntityTrapReasonDescr Indicates the description of the error code.

Impact on the System

Services are interrupted on the interface with the optical module installed.

Possible Causes

The bias current of the optical module exceeds the upper limit.

Procedure

  1. Run the display transceiver verbose command in user view to check the bias current of the optical module.
  2. If the bias current of the optical module exceeds the upper limit, replace the optical module.
  3. If the alarm persists, collect alarm information, log information, and configuration of the device and contact technical support personnel.
Translation
Download
Updated: 2019-03-06

Document ID: EDOC1100041475

Views: 69527

Downloads: 45

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next