Alarm Handling

AR100, AR120, AR160, AR1200, AR2200, AR3200, and AR3600 V300R003

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
AAA_1.3.6.1.4.1.2011.5.2.2.2.0.107 hwNACMaxUserAlarm

AAA_1.3.6.1.4.1.2011.5.2.2.2.0.107 hwNACMaxUserAlarm

Description

AAA/4/NACMaxUserAlarm: OID [OID] The number of NAC users reached the maximum.(Slot:[OCTET] User-num:[INTEGER] Threshold:[INTEGER]%)

The percentage of successfully authenticated NAC users reached the upper alarm threshold.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.2.2.2.0.107 Warning qualityOfServiceAlarm(3)

Parameters

Name Meaning
[OID] Indicates the MIB object ID of the alarm.
Slot:[OCTET] Indicates a slot ID.
User-num:[INTEGER] Indicates the number of successfully authenticated NAC users.
Threshold:[INTEGER]% Indicates the percentage of successfully authenticated NAC users.

Impact on the System

None

Possible Causes

The percentage of successfully authenticated NAC users reached the upper alarm threshold.

Procedure

  1. Run the display authentication user-alarm configuration command in any view to check the upper alarm threshold for the percentage of successfully authenticated NAC users. Adjust the threshold according to the network requirements. If the fault persists, go to 2.
  2. Collect log information and contact technical support personnel.