Alarm Handling

AR100, AR120, AR160, AR1200, AR2200, AR3200, and AR3600 V300R003

This document provides the trap description, attributes, parameters, impact on the system, possible causes, procedures, and references. This document provides a complete set of traps, through which intended readers are kept of the running status of the device so as to locate faults.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
GRE_1.3.6.1.4.1.2011.5.25.201.3.5 hwHybridSwitch2PriorTunnel

GRE_1.3.6.1.4.1.2011.5.25.201.3.5 hwHybridSwitch2PriorTunnel

Description

GRE/4/BONDING_SWITCHTO_PRIOR:OID [oid] The delay of the tunnel exceeds the threshold and traffic is switched to the priority tunnel.(PriorityInterface=[PriorityInterface], RttThreshold=[RttThreshold], RttCheckTimes=[RttCheckTimes])

When the LTE tunnel delay exceeded the delay threshold for a certain consecutive number of times, traffic switched to the DSL tunnel.

Attribute

Alarm ID Alarm Severity Alarm Type
1.3.6.1.4.1.2011.5.25.201.3.5 Warning other

Parameters

Name Meaning
oid Indicates the MIB object ID of the alarm.
PriorityInterface Index of the DSL tunnel interface
RttThreshold RTT delay detection threshold
RttCheckTimes Number of RTT delay detections

Impact on the System

Services will not be affected.

Possible Causes

The LTE tunnel delay exceeded the delay threshold for a certain consecutive number of times.

Procedure

  • This trap message is informational only, and no action is required.

Related Information

None