PAC60S12-AN (AC-DC Power,-40degC,70degC,90V,290V,12.2V/5A,PAC60S12-AN)
Overview
Item | Details |
---|---|
Description | AC-DC Power,-40degC,70degC,90V,290V,12.2V/5A,PAC60S12-AN |
Part Number | 02131664 |
Model | PAC60S12-AN |
Appearance
Version Mapping
Product | Product Model | First Supported Version | Last Supported Version | Unsupported Version |
---|---|---|---|---|
AR600 | AR631I-LTE4CN (50010695) | V300R022C10 | - | - |
AR600 | AR631I-LTE4EA (50010694) | V300R022C10 | - | - |
Panel
1. 2-pin DC output power socket |
2. AC/DC input power socket |
3. DC 12 V |
- |
Silkscreen | Name | Color | Status | Description |
---|---|---|---|---|
DC 12 V | DC 12 V indicator | Green | Steady on | The power supply is working properly. |
Green | Blinking | The power supply is in hiccup protection state. | ||
- | Off | The power supply output is abnormal. |
Silkscreen | Name | Description |
---|---|---|
ON/OFF | Power switch | Used to turn on or off the power output. |
Port | Connector Type | Description | Available Components |
---|---|---|---|
AC power socket | C13 straight female | Use an AC Power Cable to connect the router to a power source. | AC power cable |
Jack for power cable locking strap | - | Insert a power cable locking strap in this jack to secure the power cable. | Power cable locking strap |
Functions and Features
Functions and Features | Description |
---|---|
Input undervoltage protection | The power module can automatically resume power supply from this protection state. |
Input overvoltage protection | The power module can automatically resume power supply from this protection state. |
Input overcurrent protection | The power module cannot automatically resume power supply from this protection state. |
Output overvoltage protection | The power module cannot automatically resume power supply from this protection state. |
Output current limiting protection | The power module cannot automatically resume power supply from this protection state. |
Output short-circuit protection | The power module can automatically resume power supply from this protection state. |
Overtemperature protection | When the temperature of the power module exceeds a specified threshold, the power module stops supplying power. When the temperature falls into the normal range, the power module automatically resumes power supply. |
Technical Specifications
Item | Specification |
---|---|
Dimensions without packaging (H x W x D) [mm(in.)] | 40 mm x 150 mm x 130 mm (1.57 in. x 5.91 in. x 5.12 in.) |
Weight without packaging [kg(lb)] | 0.9 kg (1.98 lb) |
Rated input voltage [V] | • AC: 100 V AC to 240 V AC; 50/60 Hz • DC: 110 V DC to 250 V DC |
Input voltage range [V] | • AC: 90 V AC to 290 V AC • DC: 88 V DC to 300 V DC |
Maximum input current [A] | 2 A |
Rated output voltage [V] | 12.2 V DC |
Rated output power [W] | 60 W |
Power dissipation Mode | Natural heat dissipation |
Hot swapping | Supported |