AR-6EM-W (AR, AR-6EM-W, 6-Port EM(RJ45) Interface Card, 1*1)
Overview
Item | Details |
---|---|
Description | AR, AR-6EM-W, 6-Port EM(RJ45) Interface Card, 1*1 |
Part Number | 03022CPR |
Model | AR-6EM-W |
Silkscreen | 6E&M |
- Use tweezers to operate the DIP switches.
- On a DIP switch, the position close to ON DIP (top) represents 1, and the position close to 1 2 3 4 (bottom) represents 0.
Interface Number |
DIP Switch |
Lines |
Description |
Factory Setting |
---|---|---|---|---|
E&M0 |
SW101 |
|
|
4-wire mode |
E&M1 |
SW100 |
|||
E&M2 |
SW102 |
|||
E&M3 |
SW103 |
|||
E&M4 |
SW1 |
|||
E&M5 |
SW2 |
Appearance
Version Mapping
Product | Product Model | First Supported Version | Last Supported Version | Unsupported Version | Limitations |
---|---|---|---|---|---|
AR6200 | AR6280 (02115641) | V300R019C00 | - | - | - |
AR6200 | AR6280 (02115641-001) | V300R021C10 | - | - | - |
AR6200 | AR6280-S (02353PBR) | V300R019C10 | - | - | - |
AR6200 | AR6280-S (02353PBR-001) | V300R022C00 | - | - | - |
AR6200 | AR6280K (02116205) | V300R019C11 | - | - | - |
AR6300 | AR6300 (02115640) | V300R019C00 | - | - | - |
AR6300 | AR6300-S (02352VEL) | V300R019C00 | - | - | - |
AR6300 | AR6300-S (02352VEL-001) | V300R022C00 | - | - | - |
AR6300 | AR6300K (02116206) | V300R019C11 | - | - | - |
Indicators
1. STAT indicator |
2. E&M interface indicator |
- |
Silkscreen | Name | Color | Status | Description |
---|---|---|---|---|
STAT | STAT indicator | Green | Slow blinking | The system is running properly. |
Green | Fast blinking | The system is being powered on or restarting. | ||
Red | Steady on | A fault that affects services has occurred and cannot be rectified automatically. The fault needs to be rectified manually. | ||
- | Off | The software is not running or the card is resetting. | ||
E&M | E&M indicator | Green | Steady on | The line on the interface is occupied. NOTE:
Press the PPT key. The indicator on the local calling end blinks slowly. The indicator on the peer end blinks quickly. |
Green | Blinking | The line is being established on the interface. NOTE:
When there is a call, the indicator blinks at a different frequency than the slow/fast blinking frequency. |
||
- | Off | The line on the interface is idle. |
Ports
1. Six E&M interfaces |
- |
Port | Connector Type | Description | Available Components |
---|---|---|---|
E&M interface | RJ45 | An E&M interface sends and receives E&M signals. It can be connected to a PBX to provide audio transmission functions. Standards compliance: G.712 Interface rate: 64 kbit/s Protocols:
Interface frequency: 201 Hz to 3513 Hz |
Functions and Features
Functions and Features | Description |
---|---|
Overview | The 6E&M provides six E&M interfaces and is used for analog trunk access in small and medium-sized enterprises or enterprise branches, providing low-speed data switching and audio transmission. A 6E&M card can be installed in a WSIC slot of a router. |
Basic functions | Provides the E&M trunk function. Provides six interfaces to receive and process 64 kbit/s signals. Supports E&M signaling of Bell1, Bell2, Bell3, Bell4, and Bell5. |
Alarm and performance | Provides abundant alarms and performance logs for system maintenance and fault location. |
Technical Specifications
Item | Specification |
---|---|
Card type | WSIC |
Dimensions without packaging (H x W x D) [mm(in.)] | 201 mm x 223.5 mm x 19.82 mm (7.91 in. x 8.80 in. x 0.78 in) |
Weight without packaging [kg(lb)] | 0.6 kg (1.32 lb) |
Typical power consumption [W] | 7.2 W |
Maximum power consumption [W] | 9 W |
Long-term operating temperature [°C(°F)] | 0°C to 45°C (32°F to 113°F) |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Hard disk | Not supported |
DSP slot | Not supported |
Hot swapping | Supported |