AR6300K
Overview
Item | Details |
---|---|
Description | AR6300K integrated chassis, 2*SRU slot, 4*SIC slot, 2*WSIC slot, 4*XSIC slot, 2*power slot |
Part Number | 02116206 |
Model | AR6300K |
First supported version | V300R019C11 |
Remarks | If an AR6300K is equipped with the 350 W AC power module or 350 W DC power module, ensure that the total power of cards configured on the AR6300K does not exceed 102 W or contact technical support personnel for more suggestions. All the indicators seen on the AR6300 front panel are module indicators. For details about these indicators, see indicator description of the specific module. The AR6300 system parameters depends on the SRU that is used. |
Appearance
Components
1. Two SRU slots Applicable SRUs: NOTE:
The two SRUs must be of the same model for the double SRUs scenarios, and the two SRUs of different models cannot be used together in a router. In SD-WAN scenarios, the double SRUs are not supported. |
2. Two power module slots Applicable power modules:
NOTE:
AC and DC power modules cannot be used together in a router. It is recommended to configure dual power supplies for the double SRUs scenarios. Two power modules support 1+1 backup. |
3. Fan module slot |
4. Ground point |
5. ESD jack NOTE:
When maintaining the router, wear an ESD wrist strap and insert the other end of the ESD wrist strap in the ESD jack. |
6. Product model silkscreen |
7. Four SIC slots |
8. Two WSIC slots |
9. Four XSIC slots |
Slot Layout
Slot Type | Slot ID | Slot Direction | Remarks |
---|---|---|---|
SIC | 1 | Transverse | Slot 1 and slot 2 are combined into new slot 2 (WSIC). |
SIC | 2 | Transverse | Slot 1 and slot 2 are combined into new slot 2 (WSIC). |
SIC | 3 | Transverse | Slot 3 and slot 4 are combined into new slot 4 (WSIC). |
SIC | 4 | Transverse | Slot 3 and slot 4 are combined into new slot 4 (WSIC). |
WSIC | 5 | Transverse | New slot 2 and slot 5 are combined into new slot 5 (XSIC). |
WSIC | 6 | Transverse | New slot 4 and slot 6 are combined into new slot 6 (XSIC). |
XSIC | 7 | Transverse | - |
XSIC | 8 | Transverse | - |
XSIC | 9 | Transverse | - |
XSIC | 10 | Transverse | - |
Power module | 11 | Transverse | - |
Power module | 12 | Transverse | - |
SRU | 13 | Transverse | - |
SRU | 14 | Transverse | - |
- Two SIC slots can be combined into one WSIC slot by removing the guide rail between them.
- Two SIC slots and the WSIC slot below them can be combined into one XSIC slot by removing the guide rails.
- After two slots are combined into one, the new slot ID is the larger one between the two original slot IDs.
- A WSIC card can be inserted into an XSIC slot. The WSIC card is in the lower part of the slot and uses the XSIC slot ID as its own slot ID.
Technical Specifications
Item | Specification |
---|---|
Installation type | Rack |
Dimensions without packaging (H x W x D) [mm(in.)] |
|
Dimensions with packaging (H x W x D) [mm(in.)] | 230 mm x 655 mm x 590 mm (9.06 in. x 25.79 in. x 23.23 in.) |
Chassis height [U] | 3 U |
Weight with packaging [kg(lb)] | 14.27 kg (31.45 lb) |
Weight without packaging [kg(lb)] | 11 kg (24.25 lb) |
Power supply mode |
|
Number of power modules | 2 |
Rated input voltage [V] |
|
Input voltage range [V] |
|
Maximum input current [A] | Depending on the power modules that is used |
Maximum output power [W] | Depending on the power modules that is used |
Type of fans | Pluggable |
Number of fan modules | 1 |
Heat dissipation mode | Air cooling |
Airflow direction | Left to right |
Extended slots (standard configuration) |
|
Number of service board slots | 10 |
Redundant power supply |
|
RPS input | Not supported |
Noise at normal temperature (acoustic power) [dB(A)] | 66.1 dB(A) |
Long-term operating temperature [°C(°F)] | 0°C to 45°C (32°F to 113°F) NOTE:
When the altitude is 1800 m-5000 m (5906 ft.-16404.2 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Storage temperature [°C(°F)] | -40°C to +70°C (-40°F to +158°F) |
Long-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing |
Long-term operating altitude [m(ft.)] | < 5000 m (16404.2 ft.) |
MTBF [year] | 42.61 year |
MTTR [hour] | 2 hour |
Availability | 0.9999962934 |