Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
How Do I Do If the Floating IP Address Cannot Be Used for Communication When the OMMHA Is Installed Properly

How Do I Do If the Floating IP Address Cannot Be Used for Communication When the OMMHA Is Installed Properly

Question

In the OMMHA scenario, a message is displayed after successful installation, indicating that the floating IP address cannot be used for communication and eSight cannot be accessed.

Answer

  1. Log in to the standby eSight server as the root user.
  2. Run the service network restart command to restart eSight.
  3. Log in to the active eSight server as the root user.
  4. Disable active/standby switchover.
  5. Run the service network restart command to restart eSight.
  6. Run the su - ossuser -c "sh /opt/ommha/ha/bin/status.sh" command to query the status of the floating IP address until the floating IP address is normal.
  7. Recover active/standby switchover.