eSight V300R010C00 Maintenance Guide 07

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-999999999 Communication Between NMS and NE Is Abnormal

ALM-999999999 Communication Between NMS and NE Is Abnormal

Description

eSight queries device communication status every 2 minutes. When eSight detects a disconnected device, this alarm is generated. When eSight successfully reconnects the device, the alarm is automatically cleared. If the alarm is not automatically cleared and the device is still disconnected, the alarm is reported again immediately.

Attribute

Alarm ID

Alarm Severity

Alarm Type

999999999

Major

Communications alarm

Parameters

Parameter

Description

Address

IP address of the device that cannot communicate with the eSight server.

Protocol

Protocol used by the device that generates the alarm.

Port

Port number for communication between eSight and the device.

Med Node ID

Gateway for communication between eSight and the device.

Impact on the System

  • eSight cannot monitor the operating status of the device.
  • eSight cannot deliver commands to the device.

Possible Causes

The network fails or the device stops running.

Procedure

  1. View the location information about the alarm and confirm the location of the device that generates the alarm.

    1. In the alarm list on the Current Alarms page, click the alarm name. The alarm details dialog box is displayed.
    2. In Location Info of the Alarm Detail dialog box, view and record the values of Address, Protocol, Port, and Mediation Node ID.
    3. In the Alarm Detail dialog box, view and record the value of Alarm Source.

  2. Check whether the device network is normal.

    1. Choose Resource > Common from the main menu.
    2. Select a device type.
    3. In the device list, check whether the device is online.

  3. Contact the maintenance personnel to check whether the device is started.

    • If yes, go to Step 4.
    • If no, start the server and go to Step 4.

  4. Contact the maintenance personnel to check the hardware. For example, check whether the network cables are securely connected and whether the switch is working properly.

    • If the fault is rectified, go to Step 5.
    • If the fault cannot be rectified, go to Step 7.

  5. Refer to Step 2 to check whether the device network is normal again.

  6. Wait for five minutes and check whether the alarm is cleared in the current alarm list.

    • If yes, the alarm handling process is complete.
    • If no, go to Step 7.

  7. Collect the information about alarm handling, and contact the technical support personnel.

Clearing

When the fault is eliminated, the system will automatically clear the alarm. Manual clearing is not required.