Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-505001105 DataBase Dump Failed

ALM-505001105 DataBase Dump Failed

Description

This alarm is generated when alarm, log, or performance data overflow dump fails. This alarm is automatically cleared if the next dump is successful.

Attribute

Alarm ID

Alarm Severity

Alarm Type

505001105

Major

Processing error alarm

Parameters

None.

Impact on the System

The dump failure may lead to insufficient database spaces, which will affect eSight functions.

Possible Causes

  • The database is abnormal.
  • The database is busy, which leads to a database operation failure.
  • When the database and eSight are deployed separately, the database is busy, which leads to a database operation failure.

Procedure

  1. Determine whether the database and eSight are deployed separately.

  2. Check whether the network connection is normal.

    • If yes, go to Step 3.
    • If no, contact the maintenance personnel to check the hardware. For example, check that network cables are securely connected and that the switch is working properly. After the network recovers, set a scheduled dump task and check whether the dump is successful. If the dump fails, go to Step 3.

  3. Contact the maintenance personnel to check whether the NE server is started.

    • If yes, go to Step 4.
    • If no, contact the maintenance personnel to recover the database. After the database recovers, set a scheduled dump task and check whether the dump is successful. If the dump fails, go to Step 4.

  4. Collect the information about alarm handling, and contact the technical support personnel.

Clearing

When the fault is eliminated, the system will auto-clear the alarm. Manual clearing is not required.

Related Information

None.