Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
ALM-999999994 The License Resource Overs the Threshold

ALM-999999994 The License Resource Overs the Threshold

Description

This alarm is generated when the system detects that the license usage has reached or exceeded the threshold; this alarm is automatically cleared when the system detects that the license usage is below the threshold.

NOTE:

For the thresholds for generating alarms related to license resources, see the license control information. For details, see Step 2.

Attribute

Alarm ID

Alarm Severity

Alarm Type

999999994

Major

Security service or mechanism violation

Parameters

None.

Impact on the System

After the alarm is generated and if it is not handled in a timely manner, you cannot access license resources when the license usage reaches the threshold. For example if the number of NEs connected to the eSight has reached the threshold 1000000 of license resources, you cannot connect new NEs.

Possible Causes

A license resource reaches or exceeds the threshold.

Procedure

  1. In the current alarm list, view Additional text of the alarm and check whether the usage of a license resource has reached or exceeded the threshold.
  2. Check whether the license usage has reached or exceeded the threshold.

    1. Choose System > System Management > License Management from the main menu.
    2. In the Resource Control area in the License Management page, check whether the license usage has reached or exceeded the threshold.

  3. Clear the alarm by applying for a new license file or reducing the license usage.

  4. Wait five minutes. In the current alarm list, check whether the alarm is cleared.

    • If yes, the alarm handling process is complete.
    • If no, go to Step 5.

  5. Collect the information about alarm handling, and contact the technical support personnel.

Clearing

When the fault is eliminated, the system will auto-clear the alarm. Manual clearing is not required.