Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
eSight Cannot Receive Alarms from Network Devices After SNMPv3 and Trap Parameters Are Set

eSight Cannot Receive Alarms from Network Devices After SNMPv3 and Trap Parameters Are Set

Symptom

After SNMPv3 and Trap parameters are configured on devices and they are added to eSight, eSight cannot receive alarms from these devices.

Possible Causes

The MIB view related parameters are set on the devices.

Procedure

Set MIB view related parameters on the devices.

The detailed configurations are as follows:

system view 
snmp-agent mib-view View_ALL include iso 
snmp-agent group v3 snmpv3usergroup privacy read-view View_ALL write-view View_ALL notify-view View_ALL     