No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

eSight V300R010C00 Operation Guide 07

Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Monitoring IP Phone Alarms

Monitoring IP Phone Alarms

eSight can monitor specified alarms of some IP phones, improving the IP phone O&M capability of eSight.

Prerequisites

You have the operation rights for Terminal Configuration Operation Set.

Context

  • The following IP phones support alarm monitoring: eSpace 7910, Huawei IP Phone 7920, eSpace 7950, Huawei IP Phone 7960, eSpace 8950, and eSpace 8950S.
  • eSpace 7910, Huawei IP Phone 7920, eSpace 7950, and Huawei IP Phone 7960 support the following alarms:
    • CPU overload alarm
    • Watchdog timeout alarm
  • eSpace 8950 and eSpace 8950S support the following alarms:
    • CPU overload alarm
    • Memory insufficiency alarm

Procedure

  1. Set the monitoring scope of IP phone alarms.

    1. Choose Resource > Collaboration Resource from the main menu.
    2. Choose Terminal Device Management > Monitoring Management > Monitoring Alarm Report from the navigation tree on the left.
    3. Select IP phone alarms to be monitored on the right.

      By default, eSight monitors all IP phone alarms on the right of the page.

  2. Enable Monitor Status for the IP phone group.

    NOTE:
    • To enable eSight to monitor IP phone alarms by group, you must enable Monitor Status for the IP phone group. If no IP phone group is created, create an IP phone group. For details, see Managing Groups.
    • To ensure effective maintenance of IP phone alarms, you are advised to monitor less than 500 IP phones at the same time. Otherwise, a large number of IP phone alarms may be reported, deteriorating system performance and affecting normal monitoring and O&M of eSight.
    1. Choose Terminal Device Management > Resource Management > Group Management from the navigation tree on the left.
    2. Click Custom Group or IP Address Group, and select the Monitor Status check box for the target group.
    3. In the dialog box that is displayed, click Confirm.

Result

  • After you set the alarm monitoring scope and enable Monitor Status for the IP phone group, eSight monitors alarms of IP phones supporting alarm monitoring in the IP phone group. If the alarm reported by the IP phone is not in the monitoring scope configured in 1, eSight does not process the alarm.
  • If Monitor Status is disabled for the IP phone group, eSight does not process alarms reported by IP phones in the group.

Follow-up Procedure

Task

Procedure

View IP phone alarms

After an IP phone reports an alarm, you can view the alarm on the alarm page of eSight. For details, see Alarm Management.

NOTE:

The alarm source of the IP phone alarm is Terminals.

Disable Monitor Status for the IP phone group

  1. Choose Resource > Collaboration Resource from the main menu.
  2. Choose Terminal Device Management > Resource Management > Group Management from the navigation tree on the left.
  3. Click Custom Group or IP Address Group, and deselect the Monitor Status check box for the target group.
  4. In the dialog box that is displayed, click Confirm.

    After you disable Monitor Status for the IP phone group, eSight does not monitor alarms of IP phones in the group and forcibly clear all alarms reported by these IP phones. The alarm clearing type is cleared by configuration.

Remove an IP phone from the group with Monitor Status enabled

For details, see Managing Terminal Devices.

After an IP phone is removed from the group with Monitor Status enabled, eSight does not monitor alarms of the IP phone and forcibly clear alarms reported by the IP phone. The alarm clearing type is cleared by configuration.

Delete an IP phone whose group has Monitor Status enabled

For details, see Managing Terminal Devices.

After an IP phone is deleted, eSight does not monitor alarms of the IP phone and forcibly clear all alarms reported by the IP phone. The alarm clearing type is cleared by configuration.

Modify the alarm monitoring scope.

  1. Choose Resource > Collaboration Resource from the main menu.
  2. Choose Terminal Device Management > Monitoring Management > Monitoring Alarm Report from the navigation tree on the left.
  3. Modify IP phone alarms to be monitored on the right.

    For alarms that need to be monitored before modification but does not need to be monitored after modification, eSight forcibly clear all the alarms. The alarm clearing type is cleared by configuration.

Restart an IP phone

After an IP phone is restarted, eSight forcibly clears all active alarms reported by the IP phone before restart. The alarm clearing type is cleared by resetting.