Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Setting Telnet Parameters on Devices

Setting Telnet Parameters on Devices

Telnet parameters are set on devices to ensure that eSight can deliver configurations to them. Telnet parameters on devices must be the same as those on eSight.

Telnet is not secure, and may have security risks. You are advised to use the more secure SSH.

The STelnet protocol provides the same functions as the SSH protocol. The detailed configurations are not mentioned here.

The following uses Huawei S5720-52X-PWR-SI-AC V200R011C10 as an example to describe the configuration. For other device models, see the configuration manual.

  • sTelnet
    <Device> system-view
    [Device] dsa local-key-pair create   //Set the length of the key pair to 2048.
    [Device] user-interface maximum-vty 15   //Set the maximum number of VTY user interfaces to 15.
    [Device] user-interface vty 0 14
    [Device-ui-vty0-14] authentication-mode aaa
    [Device-ui-vty0-14] protocol inbound ssh
    [Device-ui-vty0-14] quit
    [Device] aaa
    [Device-aaa] local-user sshuser password irreversible-cipher Changeme123   //sshuser indicates the user name and Changeme123 indicates the password. The user name and password are configured when the device interconnection Telenet protocol is configured on eSight. 
    [Device-aaa] local-user sshuser service-type ssh
    [Device-aaa] local-user sshuser privilege level 15   //Set the STelnet permission of the user to the highest level 15. You are advised to set the STelnet permission based on the site requirements.
    [Device-aaa] quit
    [Device] ssh user sshuser authentication-type password
    [Device] stelnet server enable
    [Device] ssh user sshuser service-type stelnet
    [Device] quit
    <Device> save
  • Telnet
    <Device> system-view
    [Device] telnet server enable
    [Device] user-interface maximum-vty 15   //Set the maximum number of VTY user interfaces to 15.
    [Device] user-interface vty 0 14
    [Device-ui-vty0-14] protocol inbound telnet
    [Device-ui-vty0-14] shell
    [Device-ui-vty0-14] authentication-mode aaa
    [Device-ui-vty0-14] quit
    [Device] aaa
    [Device-aaa] local-user sshuser password irreversible-cipher Changeme123   //sshuser indicates the user name and Changeme123 indicates the password. The user name and password are configured when the device interconnection Telenet protocol is configured on eSight. 
    [Device-aaa] local-user sshuser service-type telnet
    [Device-aaa] local-user sshuser privilege level 15   //Set the STelnet permission of the user to the highest level 15. You are advised to set the STelnet permission based on the site requirements.
    [Device-aaa] quit
    [Device] quit
    <Device> save