Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Global Parameters

Global Parameters

You can set and modify the following parameters: PnP, configure and upgrade parameters, log export parameters, and Industry Terminal file server information.

Prerequisites

  • You have logged in to the eSight client.
  • You have been assigned the operation rights.

Procedure

  1. Choose Resource > eLTE > eLTE System Settings > Global Parameters from the main menu.
  2. Configure PnP parameters.

    Table 19-56 PnP configuration

    Task

    Description

    Firmware Upgrade

    If you set it to ON, the Industry Terminal will be upgraded to the specified firmware version.

    • If a firmware version file has been uploaded to eSight, eSight automatically compares the Industry Terminal's firmware version with the version on eSight after the Industry Terminal registers. If the two versions are different, eSight automatically upgrades the Industry Terminal's firmware version to the specified version.
    • If a firmware version file is not uploaded to eSight, eSight does not perform the upgrade.

    Configuration File Update

    If you set it to ON, the preconfiguration file will be delivered to the Industry Terminal.

    • If a preconfiguration file has been uploaded to the Industry Terminal subnet, eSight delivers the preconfiguration file to the Industry Terminal after the Industry Terminal registers.
    • If a preconfiguration file is not uploaded to the Industry Terminal subnet, eSight does not deliver the preconfiguration file to the Industry Terminal after the Industry Terminal registers.

  3. Update the PGP public key file.

    1. In PGP Public Key File Update, click and select a target public key file.
    2. Click Apply.
      NOTE:

      Huawei's public key file is pre-integrated to implement signature verification.

      To obtain the public key file, log in to http://suport.huawei.com/enterprise, choose Tools > Tools software > Enterprises Common > Software digital signature (OpenPGP) validation tool, and download KEYS.

  4. In Industry Terminal File Server Info, set Concurrency, and click Apply.
  5. Configure TLSv1 switch.

    Table 19-57 TLSv1 switch configuration

    Task

    Description

    TLSv1 switch

    ON indicates that the file server information of the old industry terminal versions is compatible.

    NOTE:
    • TLSv1 is an insecure protocol and is only for compatible with older versions of industry terminal, and can cause file server restarts after modification, file loading and firmware upgrade may fail. Do not modify it at will.
    • By default, the TLSv1 function is disabled.

  6. Changing the Industry Terminal file server user password.

    1. Enter Old password. Enter New user name and New password as needed.

      Enter the new password again in Confirm password.

    2. Click Apply.