To ensure the normal running of the eSight system, the network must meet the basic bandwidth requirements.
Table 7-6 Network bandwidth requirementsItem
|
Required Bandwidth
|
Bandwidth between the eSight server and devices
|
Total bandwidth between eSight and devices = Device management bandwidth + Additional bandwidth for terminal upgrade + Additional bandwidth for network traffic + Additional bandwidth for servers
Recommended bandwidth: 50 Mbit/s
- Device management bandwidth (X indicates the total number of devices, including terminals and other box devices):
- X < 2000, minimum bandwidth required: 2 Mbit/s
- X > 2000, minimum bandwidth required: 2 Mbit/s + (X – 2000) x 0.8 kbit/s
- Additional bandwidth for terminal (IP phones and CPEs) upgrade (Y indicates the number of terminals):
(Y/10) x 256 kbit/s
NOTE: The planned bandwidth for each terminal upgrade is 256 kbit/s. In the formula, Y/10 indicates that 10% terminals are concurrently upgraded. eSight allows users to upgrade 100 terminals at the same time, requiring 25.6 Mbit/s.
- Additional bandwidth for network traffic:
N x 400 bit/s
NOTE: - In the formula, N indicates the number of flows and its unit is flow/s.
- The bandwidth for a flow is calculated as follows: (1500/30) x 8 bit/s = 400 bit/s. Here, 1500 indicates that the average size of a NetStream packet is 1500 bytes, and 30 indicates that a NetStream packet has 30 flows on average.
- Reference: The number of flows varies according to the service. For a scenario in which a 50 GB bandwidth is required for monitoring and the sampling ratio is 1000:1, for 10,000 to 30,000 flows, the bandwidth of 3.8 Mbit/s to 10 Mbit/s is required.
- Additional bandwidth for deploying the operating system for servers:
15 Mbit/s
NOTE: eSight allows users to load and deploy the operating system image through the ServiceCD. Deploying the operating system for each server requires 1.5 Mbit/s. eSight allows users to deploy the operating system for a maximum of 10 servers at the same time, requiring 15 Mbit/s (10 x 1.5 Mbit/s).
|
Bandwidth between the eSight server and web client
|
Bandwidth for communication between the eSight server and client = Bandwidth between a single eSight client and eSight server x Number of clients
The communication bandwidth between a single eSight client and eSight server must be at least 2 Mbit/s. It is recommended that the bandwidth be greater than 10 Mbit/s.
NOTE: Requirements for eSight to access the network: delay < 30 ms, packet loss rate < 0.1%
|
Bandwidth between the eSight server and OSS
|
≥ 100 Mbit/s
|
Bandwidth between the upper-layer and lower-layer NMSs of eSight
|
≥ 10 Mbit/s
|
Bandwidth between the active and standby servers in the HA system
|
≥ 100 Mbit/s
NOTE: Network between the active and standby servers in the HA system: delay < 30 ms, packet loss rate < 0.1%
|