Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Viewing HyperMetro Consistency Group Information

Viewing HyperMetro Consistency Group Information

Scenarios

This operation is used to view information about existing HyperMetro consistency groups, facilitating the monitoring of their statuses.

Prerequisites

  • You have logged in to FusionStorage Block Self-Maintenance Platform.
  • You have created a HyperMetro consistency group.

Procedure

    1. On FusionStorage Block Self-Maintenance Platform, choose DR Service > dr > DR Cluster, click Manage HyperMetro in the row where the cluster resides.
    2. View information about existing consistency groups.

      Table 3-4 shows the parameters.

      Table 3-4  Consistency group parameters

      Name

      Description

      Name

      Consistency group name

      ID

      Consistency group ID

      Preferred Site

      Preferred site of the consistency group

      HyperMetro Domain

      HyperMetro domain where the consistency group belongs

      Health Status

      Indicates whether the consistency group is working properly. The value can be Normal or Faulty.
      • Normal: The consistency group is working properly, and data synchronization can be performed.
      • Faulty: The consistency group is not working properly or a link fault occurs, and data synchronization cannot be performed.

      Work Status

      Indicates the running status of the consistency group. The value can be Normal, To Be Synchronized, Paused, Synchronizing, Forced to Start, or Invalid.
      • Normal: Data in the consistency group at two sites has been synchronized.
      • To Be Synchronized: Data in the consistency group at two sites is inconsistent and needs to be synchronized.
      • Paused: The consistency group is paused, and data synchronization is suspended.
      • Synchronizing: The consistency group data synchronization is in progress.
      • Forced to Start: The local or remote volumes in the consistency group are forced to provide services.
      • Invalid: The consistency group cannot be used and restored. You can only delete the consistency group.

    3. Locate the target consistency group and click More > View HyperMetro Pair Information in the Operation column to view the HyperMetro pair information.