Technical Specifications
Table 4-1 Basic features (1) and Table 4-2 Basic features (2) list the basic features of a RAID controller card.
Feature |
LSI SAS3008IR |
LSI SAS3108 |
Avago SAS3508 |
Avago SAS3516 |
Avago MegaRAID SAS 9460-16i |
Avago MegaRAID SAS 9460-8i |
Avago SAS3408iMR |
Avago SAS3416iMR |
Avago MegaRAID SAS 9440-8i |
---|---|---|---|---|---|---|---|---|---|
Interface rate (Gbit/s) |
12 |
12 |
12 |
12 |
12 |
12 |
12 |
12 |
12 |
Number of supported RAID arrays |
2 |
64 |
64 |
64 |
64 |
64 |
32 |
32 |
32 |
Maximum number of drives in a RAID array |
10 |
32/240a |
32/240b |
32 |
32 |
240 |
32 |
32 |
32 |
Maximum number of drives in all RAID arraysd |
14 |
32/240a |
32/240b |
32 |
240 |
240 |
32 |
32 |
32 |
JBOD |
Supported |
Supported |
Supported |
Supported |
Supported |
Supported |
Supported |
Supported |
Supported |
Number of drives supported in JBOD mode |
1000 |
32/240a |
32/240b |
32 |
240 |
240 |
63 |
63 |
63 |
Maximum number of drives supported |
1000 |
32/240a |
32/240b |
32 |
240 |
240 |
63 |
63 |
63 |
CacheCade |
Not supported |
Supportedf |
Not supported |
Not supported |
Not supported |
Not supported |
Not supported |
Not supported |
Not supported |
Adjustable cache read/write ratio |
N/A |
Not supported |
N/A |
N/A |
N/A |
N/A |
N/A |
N/A |
N/A |
Maximum number of SSDs supported by CacheCade |
N/A |
32 |
N/A |
N/A |
N/A |
N/A |
N/A |
N/A |
N/A |
Maximum CacheCade capacity |
N/A |
512 GB |
N/A |
N/A |
N/A |
N/A |
N/A |
N/A |
N/A |
RAID levels supported by CacheCade |
N/A |
0/1 |
N/A |
N/A |
N/A |
N/A |
N/A |
N/A |
N/A |
Hot sparing supported by CacheCade |
N/A |
Supported |
N/A |
N/A |
N/A |
N/A |
N/A |
N/A |
N/A |
FastPath |
Supported |
Supported |
Supported |
Supported |
Supported |
Supported |
Supported |
Supported |
Supported |
4K drives |
Supported |
Supported |
Supported |
Supported |
Supported |
Supported |
Supported |
Supported |
Supported |
Supported RAID levels |
0/1/10/1 E |
0/1/10/5/50/6/60 |
0/1/10/5/50/6/60 |
0/1/10/5/50/6/60 |
0/1/10/5/50/6/60 |
0/1/10/5/50/6/60 |
0/1/10 |
0/1/10 |
0/1/10 |
Strip size customization |
Not supported (64 KB by default) |
Supported (Value: 64 KB/128 KB/256 KB/512 KB/1024 KB. The default value is 256 KB.) |
Supported (Value: 64 KB/128 KB/256 KB/512 KB/1024 KB. The default value is 256 KB.) |
Supported (Value: 64 KB/128 KB/256 KB/512 KB/1024 KB. The default value is 256 KB.) |
Supported (Value: 64 KB/128 KB/256 KB/512 KB/1024 KB. The default value is 256 KB.) |
Supported (Value: 64 KB/128 KB/256 KB/512 KB/1024 KB. The default value is 256 KB.) |
Not supported (64 KB by default) |
Not supported (64 KB by default) |
Not supported (64 KB by default) |
Power failure protection by iBBU |
Not supported |
Not supported |
Not supported |
Not supported |
Not supported |
Not supported |
Not supported |
Not supported |
Not supported |
Power failure protection by supercapacitor |
Not supported |
Supported |
Supported |
Supported |
Supported |
Supported |
Not supported |
Not supported |
Not supported |
Global hot spare |
Supportede |
Supportede |
Supportede |
Supportede |
Supportede |
Supportede |
Supportede |
Supportede |
Supportede |
Dedicated hot spare |
Not supported |
Supportede |
Supportede |
Supportede |
Supportede |
Supportede |
Supportede |
Supportede |
Supportede |
Emergency hot spare |
Not supported |
Supported |
Supported |
Supported |
Supported |
Supported |
Supported |
Supported |
Supported |
Number of supported hot spare drives |
2 |
32/240a |
32/240b |
32 |
240 |
240 |
63 |
63 |
63 |
Online RAID level migration |
Not supported |
Supported |
Supported |
Supported |
Supported |
Supported |
Supported |
Supported |
Supported |
Online capacity expansion |
Not supported |
Supported |
Supported |
Supported |
Supported |
Supported |
Supported |
Supported |
Supported |
Automatic SMART scan |
Supported |
Supported |
Supported |
Supported |
Supported |
Supported |
Supported |
Supported |
Supported |
Patrol read |
Supported |
Supported |
Supported |
Supported |
Supported |
Supported |
Supported |
Supported |
Supported |
Consistency check |
Supportede |
Supportede |
Supportede |
Supportede |
Supportede |
Supportede |
Supportede |
Supportede |
Supportede |
Crypto encryption |
Not supported |
Not supported |
Not supported |
Not supported |
Not supported |
Not supported |
Not supported |
Not supported |
Not supported |
Out-of-band management |
Not supported |
Supportedc |
Supported |
Supported |
Supported |
Supported |
Supported |
Supported |
Supported |
Cache |
Not supported |
Supported (1 GB/2 GB) |
Supported (2 GB/4 GB) |
Supported (2 GB/4 GB) |
Supported (2 GB/4 GB) |
Supported (2 GB/4 GB) |
Not supported |
Not supported |
Not supported |
Buzzer |
Not supported |
Not supported |
Not supported |
Not supported |
Supported |
Supported |
Not supported |
Not supported |
Not supported |
a: The LSI SAS3108 supports two types of RAID keys, which support 32 and 240 drives respectively. For details, see Table 6-4 Supported RAID levels and quantity of drives in RAID 0, 1, 5, 6, 10, 50, and 60. b: The Avago SAS3508 supports two types of RAID keys, which support 32 and 240 drives respectively. For details, see Table 7-2 Supported RAID levels and quantity of drives in RAID 0, 1, 5, 6, 10, 50, and 60. c: The LSI SAS3108 PCB version .B and later support out-of-band management. The LSI SAS3108 PCB version .A does not support out-of-band management. d: Maximum number of drives in all RAID arrays (for an LSI SAS3008IR RAID controller card) = Number of hot spare drives + Number of drives in RAID arrays. Maximum number of drives in all RAID arrays (for other RAID controller cards) = Number of hot spare drives + Number of idle drives (drives in Unconfigured Good state) + Number of drives in RAID arrays. e: RAID 0 is excluded. f: To obtain the code of the RAID controller card that supports the CacheCade, use the Computing Product Compatibility Checker. |
Feature |
MSCC SmartRAID 3152-8i |
MSCC SmartHBA 2100-8i |
---|---|---|
Interface rate (Gbit/s) |
12 |
12 |
Number of supported RAID arrays |
64 |
64 |
Maximum number of drives in a RAID array |
128 |
128 |
Maximum number of drives in all RAID arrays |
238 |
238 |
JBOD |
Supported |
Supported |
Number of drives supported in JBOD mode |
238 |
238 |
Maximum number of drives supported |
238 |
238 |
maxCachea |
Supported |
Not supported |
Adjustable cache read/write ratio |
Supported |
N/A |
Maximum number of SSDs supported by maxCache |
128 |
N/A |
Maximum maxCache capacity |
6.8 TB |
N/A |
RAID levels supported by maxCache |
0/1/10/5 |
N/A |
Hot spare supported by maxCache |
Not supported |
N/A |
SSD I/O Bypass |
Supported |
Supported |
4K drives |
Supported |
Supported |
Supported RAID levels |
RAID 0/1/1 ADM/10/10 ADM/5/50/6/60 |
RAID 0/1/10 |
Strip size customization |
Supported (Value: 16 KiB/32 KiB/64 KiB/128 KiB/256 KiB/512 KiB/1024 KiB. The default value is 256 KiB.) |
Supported (Value: 16 KiB/32 KiB/64 KiB/128 KiB/256 KiB/512 KiB/1024 KiB. The default value is 256 KiB.) |
Power failure protection by iBBU |
Not supported |
Not supported |
Power failure protection by supercapacitor |
Supported |
Not supported |
Global hot spare |
Supported |
Supported |
Dedicated hot spare |
Supported |
Supported |
Emergency hot spare |
N/A |
N/A |
Number of supported hot spare drives |
32 |
32 (up to 4 hot spare drives per array) |
Online RAID level migration |
Supported |
Not supported |
Online capacity expansion |
Supported |
Not supported |
Automatic SMART scan |
Supported |
Supported |
Patrol read |
Supported |
Supported |
Consistency check |
Supported |
Supported |
Crypto encryption |
Not supported |
Not supported |
Out-of-band management |
Not supported |
Not supported |
520-byte sector drive |
Not supported |
Not supported |
Buzzer |
Not supported |
Not supported |
a: The Microsemi defines CacheCade as maxCache. |
N/A in the table stands for not applicable.
Table 4-3 RAID level comparison lists the reliability, read/write performance, and drive utilization of RAID levels supported by RAID controller cards.
RAID Level |
Reliability |
Read Performance |
Write Performance |
Drive Utilization |
---|---|---|---|---|
RAID 0 |
Low |
High |
High |
100% |
RAID 1 |
High |
High |
Medium |
50% |
RAID 1 ADM |
High |
High |
Medium |
33% |
RAID 5 |
Medium |
High |
Medium |
(N – 1)/N |
RAID 6 |
Medium |
High |
Medium |
(N – 2)/N |
RAID 10 |
High |
High |
Medium |
50% |
RAID 1E |
High |
Medium |
Medium |
50% |
RAID 10 ADM |
High |
High |
Medium |
33% |
RAID 50 |
High |
High |
Relatively high |
(N – M)/N |
RAID 60 |
High |
High |
Relatively high |
(N – M x 2)/N |
Note: N indicates the number of member drives in a RAID array. M indicates the number of spans in the RAID array. |
Table 4-4 Supported interface types of drives lists the interface types of drives supported by each RAID controller card.
Interface Type |
SAS HDD |
SATA HDD |
SAS SSD |
SATA SSD |
NVMe PCIe SSD |
M.2 SATA SSD |
---|---|---|---|---|---|---|
LSI SAS3008IR |
Supported |
Supported |
Supported |
Supported |
Not supported |
Not supported |
LSI SAS3108 |
Supported |
Supported |
Supported |
Supported |
Not supported |
Not supported |
Avago SAS3508 |
Supported |
Supported |
Supported |
Supported |
Not supported |
Not supported |
Avago SAS3516 |
Supported |
Supported |
Supported |
Supported |
Not supported |
Not supported |
Avago SAS3408iMR |
Supported |
Supported |
Supported |
Supported |
Not supported |
Not supported |
Avago SAS3416iMR |
Supported |
Supported |
Supported |
Supported |
Not supported |
Not supported |
Avago MegaRAID SAS 9440-8i |
Supported |
Supported |
Supported |
Supported |
Not supported |
Not supported |
Avago MegaRAID SAS 9460-8i |
Supported |
Supported |
Supported |
Supported |
Not supported |
Not supported |
Avago MegaRAID SAS 9460-16i |
Supported |
Supported |
Supported |
Supported |
Not supported |
Not supported |
MSCC SmartRAID 3152-8i |
Supported |
Supported |
Not supported |
Supported |
Not supported |
Not supported |
MSCC SmartHBA 2100-8i |
Supported |
Supported |
Not supported |
Supported |
Not supported |
Not supported |
For details about drive models supported by each RAID controller card, see Computing Product Compatibility Checker.