Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Planning Storage Pools

Planning Storage Pools

Before using a storage system, create storage pools to provide storage space. The RAID policies of the storage pools must be properly planned for better storage utilization.

Dorado V3 storage systems use dynamic RAID for redundancy and provide different levels of protection based on the number of parity bits in the RAID group. Table 3-3 describes RAID 5, RAID 6, and RAID-TP provided by storage systems when hot spare space is not considered.

Table 3-3 RAID levels

RAID Level

Number of Parity Bits

Redundancy and Data Recovery Capability

Maximum Number of Allowed Faulty Disks

RAID 5

1

Relatively high. Parity data is distributed on different chunks. In each chunk group, the parity data occupies the space of one chunk. RAID 5 is able to tolerate the failure on only one chunk. If two or more chunks fail, RAID 5 protection can no longer be provided.

1

RAID 6

2

High. Parity data is distributed on different chunks. In each chunk group, the parity data occupies the space of two chunks. RAID 6 is able to tolerate simultaneous failures on two chunks. If three or more chunks fail, RAID 6 protection can no longer be provided.

2

RAID-TP

3

High. Parity data is distributed on different chunks. In each chunk group, the parity data occupies the space of three chunks. RAID-TP is able to tolerate simultaneous failures on three chunks. If four or more chunks fail, RAID-TP fails.