Basic Storage Service Configuration Guide for Block

OceanStor Dorado V3 Series V300R002

This document is applicable to OceanStor Dorado3000 V3, Dorado5000 V3, Dorado6000 V3, and Dorado18000 V3. It describes the basic storage services and explains how to configure and manage them.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Check Before Configuration

Check Before Configuration

Check the software installation and initial configuration to ensure that site requirements are met.

Checking Licenses

Log in to DeviceManager. Check whether licenses have been imported and contain the same basic or value-added features you purchased.

  • If licenses have not been imported, import them by following instructions in "Initializing the Storage System" in the installation guide.
  • If the licenses are different from those you purchased, contact technical support.

Checking Software Installation

Check whether the required software is properly installed on the storage system and application server. Table 4-1 lists the check items and provides the check methods.

Table 4-1 Software installation checklist

Check Item

Description

(Optional) iSCSI initiator

NOTE:

The iSCSI initiators are required only for iSCSI connection.

  • Windows

    On the Windows task bar, check whether Microsoft iSCSI Initiator exists in the All programs list.

  • SUSE

    On a SUSE application server, run the rpm -qa |grep iscsi command. If the iSCSI initiator information is displayed, an iSCSI initiator is installed on the application server.

  • Red Hat

    On a Red Hat application server, run the rpm -qa | grep iscsi command. If the iSCSI initiator information is displayed, an iSCSI initiator is installed on the application server.

  • Solaris

    On a Solaris application server, run the pkginfo | grep iscsi command. If the iSCSI initiator information is displayed, an iSCSI initiator is installed on the application server.

  • HP-UX

    On an HP-UX application server, run the swlist iSCSI-00 command. If the iSCSI initiator information is displayed, an iSCSI initiator is installed on the application server.

  • VMware

    For VMware ESXi 4.1 and earlier versions, an iSCSI adapter already exists in a storage adapter. You can directly enable the iSCSI adapter. For VMware ESXi 5.0 and later versions, you must add an iSCSI adapter on the Storage Adapters page and then perform the follow-up configuration.

For details about installing an iSCSI initiator, refer to "Configuring Connectivity" in Huawei SAN Storage Host Connectivity Guide for XXX. XXX represents a specific operating system, for example, Windows.

NOTE:
  • You can log in to Huawei's technical support website (https://support.huawei.com/enterprise/) and enter the product model + document name in the search box to search for, browse, and download documents.
  • You can follow the same procedure to search for and download other Huawei documents referenced in this document.

(Optional) UltraPath

NOTE:
  • Multipathing software is required when redundant paths exist between the storage system and the application server.
  • UltraPath is Huawei-developed multipathing software.

For details about installing UltraPath, refer to the OceanStor UltraPath for XXX User Guide. XXX represents a specific operating system, for example, Windows.

NOTE:

You can log in to Huawei's technical support website at https://support.huawei.com/enterprise/. In the search box, enter UltraPath, and select a path from the paths that are automatically displayed to go to the document page. Then click the Software Download tab, and search for and download your desired software files.

Checking Network Connection Status

Table 4-2 lists the check items and provides the check methods.

Table 4-2 Network connection status checklist

Category

Check Item

Check Method

Connection between the maintenance terminal and the storage system

Check whether the management network port on the storage system is communicating with the maintenance terminal properly.

In the CLI of the maintenance terminal, run ping ip (if IPv4 is used) or ping -6 ip (if IPv6 is used), where ip indicates the IP address of the management network port.

  • If the maintenance terminal receives data packets from the management network port, this indicates that the communication between the storage system and maintenance terminal is normal.
  • If the maintenance terminal receives no data packets from the management network port, change the IP address of the management network port and try again.

Connection between the storage system and the application server (using a Windows application server as an example)

When an iSCSI front-end port on the storage system is used for connection, check whether the iSCSI front-end port is communicating with the service network port on the application server properly.

In the CLI of the application server, run ping ip (if IPv4 is used) or ping -6 ip (if IPv6 is used), where ip indicates the IP address of the iSCSI front-end port.

  • If the application server receives data packets from the iSCSI front-end port, this indicates that the communication between the storage system and application server is normal.
  • If the application server receives no data packets from the iSCSI front-end port, replace the network cable, change the IP address of the iSCSI front-end port, or add a route between the iSCSI front-end port and service network port, and try again.

    For details on how to change the IP address of an iSCSI front-end port or add a route between an iSCSI front-end port and a service network port, see the DeviceManager online help.

When a Fibre Channel front-end port on the storage system is used for connection, check whether the rate of the Fibre Channel front-end port is the same as that of the Fibre Channel host bus adapter (HBA) on the application server.

If the rates are different, change the rate of the Fibre Channel front-end port. For details on how to change the rate of a Fibre Channel front-end port, see the DeviceManager online help.

When a Fibre Channel front-end port on the storage system is used for connection, check whether the mode of the Fibre Channel front-end port is the same as that of the Fibre Channel HBA on the application server.

If the modes are different, change the mode of the Fibre Channel front-end port. For details on how to change the mode of a Fibre Channel front-end port, see the DeviceManager online help.