No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Command Reference for Block

OceanStor Dorado V3 Series V300R002

This document is applicable to OceanStor Dorado3000 V3, Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. Based on the CLI provided by the DeviceManager, this document describes how to use various commands classified by functions and how to set the CLI and manage the storage system through these commands.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
add kmc general

add kmc general

Function

The add kmc general command is used to add the configuration of an external key management server.

Format

add kmc general type=? port=? { kmc_server_ip=? | kmc_server_domain_name=? }

Parameters

Parameter

Description

Value

kmc_server_ip=?

IP address of the external key management server.

-

kmc_server_domain_name=?

Domain name of the external key management server.

The domain name is a case-insensitive string of 1 to 255 characters, including letters, digits and hyphens (-). Domain names at various levels are separated by periods (.). Hyphens (-) cannot be the start or end of the domain name.

type=?

Type of the external key management server.

The value can be "Thales_kmip" or "SafeNet_kmip", where:

  • "Thales_kmip": Thales external key management server.
  • "SafeNet_kmip": SafeNet external key management server.

port=?

Port number of the external key management server.

The value ranges from 1 to 65535.

Level

Administrator

Usage Guidelines

  • Parameters "kmc_server_ip" and "kmc_server_domain_name" are mutually exclusive.

Example

Add a configuration of the external key management server.

admin:/>add kmc general type=Thales_kmip port=5696 kmc_server_ip=192.168.20.10 
Command executed successfully.

System Response

None

Translation
Download
Updated: 2019-07-16

Document ID: EDOC1100049140

Views: 114051

Downloads: 134

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next