Command Reference for Block

OceanStor Dorado V3 Series V300R002

This document is applicable to OceanStor Dorado3000 V3, Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. Based on the CLI provided by the DeviceManager, this document describes how to use various commands classified by functions and how to set the CLI and manage the storage system through these commands.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
change hyper_metro_consistency_group synchronize

change hyper_metro_consistency_group synchronize

Function

The change hyper_metro_consistency_group synchronize command is used to start the synchronization of a HyperMetro consistency group.

Format

change hyper_metro_consistency_group synchronize consistency_group_id=?

Parameters

Parameter

Description

Value

consistency_group_id=?

ID of the HyperMetro consistency group.

Run the "show hyper_metro_consistency_group general" command without parameters to obtain the value.

Level

Administrator

Usage Guidelines

None

Example

Start the synchronization of HyperMetro consistency "1".

admin:/>change hyper_metro_consistency_group synchronize consistency_group_id=1 
WARNING: You are about to start data synchronization.  
Once data synchronization is started, the system will synchronize data based on the synchronization direction of the consistency group and the data at the synchronized end cannot be restored.  
Suggestion: Before performing this operation, ensure that the parameters are correct to prevent data loss. 
Have you read warning message carefully?(y/n)y 
Are you sure you really want to perform the operation?(y/n)y 
Command executed successfully.

System Response

None