Command Reference for Block

OceanStor Dorado V3 Series V300R002

This document is applicable to OceanStor Dorado3000 V3, Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. Based on the CLI provided by the DeviceManager, this document describes how to use various commands classified by functions and how to set the CLI and manage the storage system through these commands.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
show upgrade redundant_link

show upgrade redundant_link

Function

The show upgrade redundant_link command is used to show whether the controller has front-end redundant links.

Format

show upgrade redundant_link

Parameters

None

Level

Guest

Usage Guidelines

Query whether every controller has front-end redundant links in default batch.After the command is executed, the command output contains two columns, and the first column Name represents the name of the controller.For example,0A,0B,1A,2B.The second column Result indicates whether the controller has redundant links, such as: True represents redundant links, and False indicates no redundant links

Example

Query whether every controller has front-end redundant links.

admin:/>show upgrade redundant_link 
  Name Result 
  -----  ------ 
  0A     True     
  0B     True     
  0C     True     
  0D     True 

System Response

The following table describes the parameter meanings.

Parameter

Meaning

Name

Name represents the name of the controller.For example,0A,0B,1A,2B.

Result

Result indicates whether the controller has redundant links, such as: True represents redundant links, and False indicates no redundant links.