No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Command Reference for Block

OceanStor Dorado V3 Series V300R002

This document is applicable to OceanStor Dorado3000 V3, Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. Based on the CLI provided by the DeviceManager, this document describes how to use various commands classified by functions and how to set the CLI and manage the storage system through these commands.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
show remote_device elink

show remote_device elink

Function

The show remote_device elink command is used to query the information about the heterogeneous links connected to a storage system.

Format

show remote_device elink [ link_type=? ] [ link_id=? ] [ remote_device_id=? ]

Parameters

Parameter

Description

Value

remote_device_id=?

ID of a remote device.

Run the "show remote_device general" command to obtain the value.

link_type=?

Link type.

The value is "FC" or "iSCSI", where:

  • "FC": A remote device is connected to a local device by Fibre Channel links.
  • "iSCSI": A remote device is connected to a local device by iSCSI links.

link_id=?

Link ID.

Run the "show remote_device elink" command without parameters to obtain the value.

Level

Guest

Usage Guidelines

  • The "link_id" parameter can be set only when the "link_type" is set.
  • The following parameters or parameter sets are mutually exclusive: "link_id" and "remote_device_id".
  • Run the "show remote_device elink" command to query the information about all links connected to the storage system.
  • Run the "show remote_device elink link_type=? link_id=?" command to query the information about a specified link.
  • Run the "show remote_device elink remote_device_id=?" command to query the information about links on a specified remote device.

Example

Query the information about heterogeneous links whose type is "FC" and whose ID is "514".

admin:/>show remote_device elink link_type=FC remote_device_id=514 
ID Health Status Running Status Local Controller Remote Device Type  
--------- ------------- -------------- ---------------- ----------  
268435456 Normal Link Up 0A Heterogeneity 
268435457 Normal Link Up 0B Heterogeneity 
268435458 Normal Link Up 0A Heterogeneity 
268435459 Normal Link Up 0B Heterogeneity 
In Remote Device Remote Device ID Remote Device WWN Remote Controller  
------------ ---------------- ----------------- -----------------  
Yes 514 a1003300 --  
Yes 514 a1003300 --  
Yes 514 a1003300 --  
Yes 514 a1003300 --  

System Response

Parameter

Meaning

ID

ID of the heterogeneous link.

Health Status

Health status of the heterogeneous link.

Running Status

Running status of the heterogeneous link.

Local Controller

ID of the local controller.

Remote Device Type

Type of the remote device.

In Remote Device

Whether the remote device is connected to the system.

Remote Device ID

ID of the remote device.

Remote Device WWN

WWN of the remote device.

Remote Controller

ID of the remote controller.

Local Port ID

Local port to which the link belongs.

Local Port WWPN

WWPN of the local port.

Remote Device Name

Name of the remote device to which the link belongs.

Remote Port ID

Remote port to which the link belongs.

Remote Port WWPN

WWPN of the remote port.

Bandwidth Limit Enabled

Whether flow control is enabled for the link.

Bandwidth Limit Size

Flow control bandwidth.

Bandwidth Utilization

Bandwidth usage.

Remote Device SN

SN of the remote device to which the link belongs.

Vendor

Vendor of the remote device.

Model

Product model of the remote device.

LUN Number

Number of LUNs.

Initiator Name

iSCSI initiator name.

Target Name

iSCSI target name.

Target IP

IP address of the iSCSI target.

Target Port

Port of the iSCSI target.

Chap Enabled

Whether CHAP authentication is enabled.

Chap User

CHAP user.

Recovery Policy

Recovery policy.

Local IP

IP address of the iSCSI initiator.

Local ISID

iSCSI initiator session identifier of the local device.

Remote TGPT

iSCSI target portal group tag of the remote device.

Translation
Download
Updated: 2019-07-16

Document ID: EDOC1100049140

Views: 116371

Downloads: 134

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share