Command Reference for Block

OceanStor Dorado V3 Series V300R002

This document is applicable to OceanStor Dorado3000 V3, Dorado5000 V3, Dorado6000 V3 and Dorado18000 V3. Based on the CLI provided by the DeviceManager, this document describes how to use various commands classified by functions and how to set the CLI and manage the storage system through these commands.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
show port fibre_module

show port fibre_module

Function

The show port fibre_module command is used to query details on all optical transceivers in the storage system.

Format

show port fibre_module [ port_id=? ]

Parameters

Parameter

Description

Value

port_id=?

ID of a port.

To obtain the value, run "show port fibre_module" without parameters.

Level

Guest

Usage Guidelines

  • Running the "show port fibre_module" command queries information about all optical transceivers.
  • Running the "show port fibre_module port_id=?" command queries information about a specified optical transceiver.

Example

  • Query details on all optical transceivers in the storage system. The command output varies depending on a specific product.
    admin:/>show port fibre_module 
      
      PortID      Health Status  Running Status  Type         
      ----------  -------------  --------------  ---------- 
      ENG0.A1.P0  Normal         Link Down       Multi Mode 
      ENG0.A1.P1  Normal         Link Down       Multi Mode 
      ENG0.A1.P2  Normal         Link Down       Multi Mode 
      ENG0.A1.P3  Normal         Link Down       Multi Mode 
      ENG0.B1.P0  Normal         Link Down       Multi Mode 
      ENG0.B1.P1  Normal         Link Down       Multi Mode 
      ENG0.B1.P2  Normal         Link Down       Multi Mode 
      ENG0.B1.P3  Normal         Link Down       Multi Mode 
      
      Working Rate(Mbps)  Vendor           Model            SN               Item             ExternalModel      Rev 
      ------------------  ---------------  ---------------  ---------------  ---------------  -----------------  --------------- 
      8000                AVAGO            AFBR-57D7APZ     AA1207AJ2KC      Item_plnb123 Model_value_012345  b_rev 
      8000                AVAGO            AFBR-57D7APZ     AA1207AJ2KE      Item_plnb123 Model_value_012345  b_rev 
      8000                AVAGO            AFBR-57D7APZ     AA1207AJ2JZ      Item_plnb123 Model_value_012345  b_rev 
      8000                AVAGO            AFBR-57D7APZ     AA1207AJ2JT      Item_plnb123 Model_value_012345  b_rev 
      8000             AVAGO            AFBR-57D7APZ     AD1209A0E51      Item_plnb123 Model_value_012345  b_rev 
      8000                AVAGO            AFBR-57D7APZ     AD1209A0E59      Item_plnb123 Model_value_012345  b_rev 
      8000                AVAGO            AFBR-57D7APZ     AD1209A0E54      Item_plnb123 Model_value_012345  b_rev 
      8000                AVAGO            AFBR-57D7APZ     AD1209A0E4K      Item_plnb123 Model_value_012345  b_rev
  • Query the optical transceiver whose ID is "CTE0.A.IOM0.P0". The ID and output vary depending on a specific product.
    admin:/>show port fibre_module port_id=CTE0.A.IOM0.P0 
      PortID             : CTE0.A.IOM0.P0 
      Health Status      : Normal           
      Running Status     : Link Down        
      Type               : Multi Mode       
      Working Rate(Mbps) : 8000             
      Vendor             : Hisense           
      Model              : LTF8503-BC+       
      SN                 : P2661008340                         
      Item               : --               
      ExternalModel      : --               
      Rev                : -- 

System Response

The following table describes the parameter meanings.

Parameter

Meaning

PortID

Port ID.

Health Status

Health status.

Running Status

Running status.

Type

Mode type.

Working Rate(Mbps)

Working rate.

Vendor

Vendor.

Model

Model.

SN

Serial number.

Item

Item encoding.

ExternalModel

External model.

Rev

Hardware version.

Translation
Download
Updated: 2019-07-16

Document ID: EDOC1100049140

Views: 123058

Downloads: 155

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next