No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

Performance Monitoring Guide

OceanStor Dorado V3 Series V300R002

This document describes performance monitoring of storage systems, including the monitoring method, indicator planning, configuration monitoring, and problem diagnosis.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Checking the Maximum Concurrency Capability of the Host HBA

Checking the Maximum Concurrency Capability of the Host HBA

The concurrency capability of an HBA indicates the maximum number of I/Os that each LUN can transmit at a time. If this is insufficiently low for a high concurrency scenario, it typically leads to poor performance.

Windows Hosts

In Windows, the concurrency capability of most HBAs is 128. However, in certain Windows versions, this value may be relatively small. For example, in Windows Server 2012 R2, the corresponding value of an Emulex HBA is 32. Insufficient concurrency capability leads to the issue of the host pressure not being fully transferred to the storage side. If the difference between the latency on both sides is large, you can use the management software provided by the HBA vendor to query the concurrency capability of the HBA and set it to an appropriate value as necessary.

Linux Hosts

In Linux, the queue parameter settings of an HBA vary depending on its type and driver. For details, see the specifications provided by the HBA vendor. For example, the QLogic 8 Gbit/s dual-port Fibre Channel HBA allows the maximum queue depth of each LUN to be 32. If the latency difference between the host side and the storage side is large, run iostat to check whether the concurrency bottleneck is reached.

In the above figure, the highlighted box shows the entries under avgqu-sz, which represent the average queue depth of the block device corresponding to a LUN. If the value of avgqu-sz is 10 or larger for a long time, it is possible that I/Os are accumulated on the block device layer of the host due to the concurrency limitation. The host pressure is not transferred to the storage side. In this case, you can increase the concurrency capability of the HBA.