Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Networking Example

Networking Example

This section describes how to plan IP addresses during installation and deployment.

This section uses the OBS service, six storage nodes, and IPv4 addresses as an example to describe how to plan IP addresses for each plane. If the HDFS service is deployed, you need to reserve IP addresses for namespaces when planning the IP addresses of the service plane.

Table 2-32 shows the IP address planning for the management plane.

Table 2-32 IP address planning for the management plane

IP Address

Port

IP Address

Subnet Mask

Gateway

Management plane floating IP address

Logical management port

10.110.100.100

255.255.255.0

10.110.100.1

Deployment tool management floating IP address

Logical management port

10.110.100.101

255.255.255.0

10.110.100.1

BMC switch management plane IP address

MEth0/0/0

10.110.100.102

255.255.255.0

10.110.100.1

Management plane IP addresses of the switches shared by the front and back ends.

MEth0/0/0

10.110.100.103

255.255.255.0

10.110.100.1

Management plane IP address of storage node 1

NIC port

10.110.100.105

255.255.255.0

10.110.100.1

Management plane IP address of storage node 2

NIC port

10.110.100.106

255.255.255.0

10.110.100.1

Management plane IP address of storage node 3

NIC port

10.110.100.107

255.255.255.0

10.110.100.1

Management plane IP address of storage node 4

NIC port

10.110.100.108

255.255.255.0

10.110.100.1

Management plane IP address of storage node 5

NIC port

10.110.100.109

255.255.255.0

10.110.100.1

Management plane IP address of storage node 6

NIC port

10.110.100.110

255.255.255.0

10.110.100.1

Table 2-33 shows the IP address planning for the BMC plane.

Table 2-33 IP address planning for the BMC plane

Name

Port

IP Address

Subnet Mask

Gateway

BMC plane IP address of storage node 1

Mgmt

10.120.100.11

255.255.255.0

10.120.100.1

BMC plane IP address of storage node 2

Mgmt

10.120.100.12

255.255.255.0

10.120.100.1

BMC plane IP address of storage node 3

Mgmt

10.120.100.13

255.255.255.0

10.120.100.1

BMC plane IP address of storage node 4

Mgmt

10.120.100.14

255.255.255.0

10.120.100.1

BMC plane IP address of storage node 5

Mgmt

10.120.100.15

255.255.255.0

10.120.100.1

BMC plane IP address of storage node 6

Mgmt

10.120.100.16

255.255.255.0

10.120.100.1

Table 2-34 shows the IP address planning for the service plane.

Table 2-34 IP address planning for the service plane

IP Address

Port

IP Address

Subnet Mask

Gateway

Service plane IP address of storage node 1

Bond port

192.168.100.11

255.255.255.0

192.168.100.1

Service plane IP address of storage node 2

Bond port

192.168.100.12

255.255.255.0

192.168.100.1

Service plane IP address of storage node 3

Bond port

192.168.100.13

255.255.255.0

192.168.100.1

Service plane IP address of storage node 4

Bond port

192.168.100.14

255.255.255.0

192.168.100.1

Service plane IP address of storage node 5

Bond port

192.168.100.15

255.255.255.0

192.168.100.1

Service plane IP address of storage node 6

Bond port

192.168.100.16

255.255.255.0

192.168.100.1

Table 2-35 shows the IP address planning for the storage plane.

Table 2-35 IP address planning for the storage plane

IP Address

Port

IP Address

Subnet Mask

Gateway

Storage plane IP address of storage node 1

Bond port

172.16.0.11

255.255.255.0

172.16.0.1

Storage plane IP address of storage node 2

Bond port

172.16.0.12

255.255.255.0

172.16.0.1

Storage plane IP address of storage node 3

Bond port

172.16.0.13

255.255.255.0

172.16.0.1

Storage plane IP address of storage node 4

Bond port

172.16.0.14

255.255.255.0

172.16.0.1

Storage plane IP address of storage node 5

Bond port

172.16.0.15

255.255.255.0

172.16.0.1

Storage plane IP address of storage node 6

Bond port

172.16.0.16

255.255.255.0

172.16.0.1

Storage plane floating IP address

Logical port

172.16.0.20

255.255.255.0

172.16.0.1

GaussDB floating IP address

Logical port

172.16.0.100

255.255.255.0

172.16.0.1

Back-end floating IP address of the deployment tool

Logical port

172.16.0.101

255.255.255.0

172.16.0.1

OAM-I floating IP address

Logical port

172.16.0.102

255.255.255.0

172.16.0.1

OAM-P floating IP address

Logical port

172.16.0.103

255.255.255.0

172.16.0.1

OAM-S floating IP address

Logical port

172.16.0.104

255.255.255.0

172.16.0.1

Table 2-36 shows IP address planning for the control plane.

Table 2-36 IP address planning for the control plane

IP Address

Port

IP Address

Subnet Mask

Gateway

Control plane IP address of storage node 1

Bond port

172.20.0.11

255.255.255.0

172.20.0.1

Control plane IP address of storage node 2

Bond port

172.20.0.12

255.255.255.0

172.20.0.1

Control plane IP address of storage node 3

Bond port

172.20.0.13

255.255.255.0

172.20.0.1

Control plane IP address of storage node 4

Bond port

172.20.0.14

255.255.255.0

172.20.0.1

Control plane IP address of storage node 5

Bond port

172.20.0.15

255.255.255.0

172.20.0.1

Control plane IP address of storage node 6

Bond port

172.20.0.16

255.255.255.0

172.20.0.1