Agile Controller EEM V200R010C10 Alarm Handling

This document provides the explanations, causes, and recommended actions of alarms on the EEM.
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
DCP_103104512 The Number of TCP Connections Exceeds the Maximum

DCP_103104512 The Number of TCP Connections Exceeds the Maximum

Description

When the number of device connections exceeds the maximum value (50,000) allowed by the DCP, this alarm is generated.

Attribute

Alarm ID Alarm Severity Alarm Type

103104512

Major

Equipment alarm

Impact on the System

Excess connections fail to be established.

Possible Causes

The DCP connects to more than 50,000 devices.

Procedure

  1. Check whether all DCP nodes in the cluster work properly.

    • If so, add DCP nodes.
    • If not, restart DCP nodes. If the fault persists, proceed to the next step.

  2. Collect alarm information and contact Huawei technical support personnel.

Clearing

The alarm needs to be cleared manually.