Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Checking the Temperature of Each Board

Checking the Temperature of Each Board

You need to check the temperature of each board.

Prerequisites

Procedure

  1. Run the display temperature [ slot slot-id ] command to view the temperature status on each board.

    <HUAWEI> display temperature slot 18
      Base-Board, Unit:C, Slot 1
    -------------------------------------------------------------------------
    PCB       I2C ADDr Chl Status   Minor Major Fatal FanTMin FanTMax Temp(C)
    -------------------------------------------------------------------------
    LPUF240A  0   72   0   NORMAL   80    90    100   70      80      33
    LPUF240A  0   73   0   NORMAL   70    80    90    60      70      36
    LPUF240A  0   74   0   NORMAL   80    90    100   70      80      36
    LPUF240A  0   75   0   NORMAL   80    90    100   70      80      32
    LPUF240A  0   76   0   NORMAL   94    99    105   80      94      37
    LPUF240A  0   79   0   NORMAL   80    90    100   70      80      34
    LPUF240A  0   175  0   NORMAL   100   105   110   75      90      44
    LPUF240A  0   175  1   NORMAL   100   105   110   80      95      43
    LBXFB     3   73   0   NORMAL   57    60    65    45      55      31
    LBXFB     3   74   0   NORMAL   80    85    90    68      78      39
    -------------------------------------------------------------------------

    Pay attention to the values of the fields displayed in boldface. The Temp(C) field indicates the current temperature. The Minor field indicates the threshold of a high temperature for a minor alarm. The Major field indicates the threshold of a high temperature for a major alarm. The Fatal field indicates the threshold of a high temperature for a critical alarm. If the board temperature reaches or exceeds the value of the Fatal field, the NE40E may work abnormally or be damaged.

    If the displayed value of the Temp(C) field is lower than that of the Minor field, the board temperature is normal. Then, go on with the subsequent commissioning.

Troubleshooting

If the board temperature exceeds the threshold, perform the following operations:

  1. Check whether fans are faulty and replace any faulty fans.

  2. Check whether the air filter is clogged. If it is clogged, clean it.

  3. Check whether the ambient temperature is too high. If the ambient temperature is too high, lower the temperature in the equipment room.

  4. If the board temperature is still high after the preceding operations, it is due to the high chip temperature. In this case, contact Huawei technical support personnel.