Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Checking the Master/Slave State of Components on a Device

Checking the Master/Slave State of Components on a Device

The following section describes how to check the master/slave state of components on a device.

Prerequisites

Procedure

  1. Run the display device [ pic-status | slot-id ] command to view the master/slave state of installed components on a device.

    <HUAWEI> display device 
    NE40E-X16's Device status:
    -----------------------------------------------------------------------------
    Slot #   Type Online     Register     Status     Role   LsId   Primary
    -----------------------------------------------------------------------------
      1      LPU  Present    Registered   Normal     LC     0      NA 
      7      LPU  Present    Registered   Normal     LC     0      NA 
      17     MPU  Present    Registered   Normal     MMB    0      Master 
      18     MPU  Present    Unregistered Abnormal   MMB    0      NA 
      19     SFU  Present    Registered   Normal     OTHER  0      NA 
      20     SFU  Present    Registered   Normal     OTHER  0      NA 
      21     SFU  Present    Registered   Normal     OTHER  0      NA 
      22     SFU  Present    Registered   Normal     OTHER  0      NA 
      23     CLK  Present    Registered   Normal     OTHER  0      Master 
      24     CLK  Present    Unregistered Abnormal   OTHER  0      NA 
      25     PWR  Present    Registered   Abnormal   OTHER  0      NA 
      27     FAN  Present    Registered   Normal     OTHER  0      NA 
      28     FAN  Present    Registered   Normal     OTHER  0      NA 
      31     FAN  Present    Registered   Normal     OTHER  0      NA 
      32     FAN  Present    Registered   Normal     OTHER  0      NA 
      33     PMU  Present    Registered   Normal     OTHER  0      Slave 
      34     PMU  Present    Registered   Normal     OTHER  0      Master 
    -------------------------------------------------------------------------------

    Focus on the Primary field to check whether the current component has a backup. Master indicates that the component is a master component, Slave indicates that the component is a slave component, and NA indicates that there is no master or slave role.