Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
(Optional) Configuring IGMP Querier Control Parameters

(Optional) Configuring IGMP Querier Control Parameters

IGMP querier control parameters include the interval at which General Query messages are sent, robustness variable, maximum response time of Query messages, keepalive time of other IGMP queriers, and interval at which IGMP last-member query messages are sent.

Context

An IGMP multicast router can either be a querier or a non-querier. IGMP queriers are elected by the IGMP protocol. When receiving a Report message from a group member, a querier refreshes group memberships. If non-queriers have not received any general query message within the Keepalive time of other IGMP queriers, they consider the current IGMP querier faulty and trigger a new round of querier election automatically. You can adjust IGMP querier control parameters based on actual network conditions or whether hosts can quickly respond. IGMP querier control parameters supported by each IGMP version are as follows:

  • IGMPv1 allows you to set only the interval at which General Query messages are sent and the robustness variable. Therefore, among the following steps for configuring IGMP querier control parameters, IGMPv1 supports only Steps 3 and 4.
  • IGMPv2 and IGMPv3 allow you to configure all IGMP querier control parameters.

Interfaces that connect multicast devices to the same user network segment must have the same IGMP parameter configurations; otherwise, these multicast devices fail to communicate.

You can configure parameters of an IGMP querier either globally or on an interface.

NOTE:

During the configuration, ensure that the interval for sending general query messages is greater than the maximum response time of Query messages but smaller than the keepalive time of other IGMP queriers.

Procedure

  • Global configuration
    1. Run system-view

      The system view is displayed.

    2. Run igmp [ vpn-instance vpn-instance-name ]

      The IGMP view is displayed.

    3. Run timer query interval

      The interval at which the device sends general query messages is set.

    4. Run robust-count robust-value

      An IGMP robustness variable is set.

      When a router starts, the router sends general query messages for the number of robust-value times. The sending interval is 1/4 of the interval for sending IGMP general query messages.

      After the router receives a Leave message,

      • In IGMPv2, a router sends group-specific query messages for the number of robust-value times. The sending interval is set using the lastmember-queryinterval command.

      • In IGMPv3, the router sends group-specific or group-and-source-specific query messages for the number of robust-value times. The sending interval is set using the lastmember-queryinterval query command.

    5. Run max-response-time interval

      The maximum response time of IGMP Query messages is set.

    6. Run timer other-querier-present interval

      The keepalive time of other IGMP queriers is set.

    7. Run lastmember-queryinterval interval

      The interval for sending IGMP last-member query messages is set.

    8. Run commit

      The configuration is committed.

  • Interface-specific configuration
    1. Run system-view

      The system view is displayed.

    2. Run interface interface-type interface-number

      The interface view is displayed.

    3. Run igmp timer query interval

      The interval at which the interface sends general query messages is set.

    4. Run igmp max-response-time interval

      The maximum response time of IGMP Query messages is set.

    5. Run igmp timer other-querier-present interval

      The keepalive time of other IGMP queriers is set.

    6. Run igmp robust-count robust-value

      An IGMP robustness variable is set.

    7. Run igmp lastmember-queryinterval interval

      The interval at which IGMP last-member query messages are sent is set.

    8. Run commit

      The configuration is committed.