Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Tracing Services of Users

Tracing Services of Users

Context

Perform the following steps on the router:

Procedure

  1. Run trace access-user object object-id { interface interface-type interface-number | ip-address ip-address | mac-address mac-address | ce-vlan ce-vlan-id | pe-vlan pe-vlan-id | ipv6-address ipv6-address/prefixlength | user-name user-name | tunnel-id tunnel-id | access-mode { pppoe | pppoa | pppoeoa | ipoe | ipoeoa } } * [ output { file file-name | syslog-server ip-address | vty } | [ -t time ] | mode packet | flow-report ] *

    Or run trace access-user object object-id { circuit-id text | remote-id text } * { exact-match | partial-match }

    Or run trace access-user object object-id calling-number [ output { file file-name | syslog-server ip-address | vty } ] [ mode packet ] [ -t time ] [ | include ] calling-number-content text

    Or run trace access-user object object-id { circuit-id text | remote-id text } * { exact-match | partial-match } [ output { file file-name | syslog-server ip-address | vty } | -t time | mode packet | flow-report ] *

    Service tracing is enabled.

    Using the service tracing function decreases the performance of the NE40E. Therefore, you are recommended to use this function only when you need to locate faults. Disable this function when the NE40E runs normally. If the status of a great number of users changes, you need to configure the objects to be traced accurately when using the service tracing function. Otherwise, a great number of resources are wasted and user services are affected.

  2. Run commit

    The configuration is committed.