Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Virtual Cluster Cross-Connect Protection Upgrade

Virtual Cluster Cross-Connect Protection Upgrade

Cross-connect protection upgrade is applicable to symmetrical networking. Upstream and downstream devices are symmetrically connected to master and backup chassis on a virtual cluster. The following figure shows the process.



Chassis A is the master, and chassis B is the backup. The upstream and downstream traffic is balanced through chassis A and B.

The upgrade process is as follows:

  1. Load a target software package on both chassis and set the file to be loaded at a next startup to the target software package.
  2. Manually close all external interfaces on chassis B. Traffic switches to chassis A. The following figure shows the process.

  3. Reset chassis B and restore the configuration file.

    After chassis B is reset, it does not detect chassis A and becomes the master. Therefore, two master chassis exist. External connections to chassis B are disconnected, and the two-master-chassis situation poses no impact after chassis B restores the configuration file.

  4. Prepare scripts used to start interfaces on chassis B.
  5. Reset chassis A and run scripts to rapidly enable all external interfaces on chassis B. Traffic switches to chassis B.

    Services are interrupted in the duration between when the interfaces on chassis B go Up and when services are restored. This is the primary cause for service interruptions in cross-connect protection upgrade. The service interruption time is related to the service volume.

  6. After chassis A is reset, it automatically joins the virtual cluster. Services are balanced between the two chassis again.