No relevant resource is found in the selected language.

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Read our privacy policy>Search

Reminder

To have a better experience, please upgrade your IE browser.

upgrade

NE40E V800R010C10SPC500 Installation Guide

This is NE40E V800R010C10SPC500 Installation Guide
Rate and give feedback:
Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document. Note: Even the most advanced machine translation cannot match the quality of professional translators. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided).
Installing the Ground Cable

Installing the Ground Cable

Ground Cable and Terminal Specifications

The following table lists the specifications of ground cables and terminals.

Item

Specification

BOM number

Remarks

Ground cable of the cabinet and chassis

25 mm2 (4 AWG)

25030431

-

Grounding terminal of the cabinet

25 mm2 (4 AWG)-M8 single-hole OT naked crimping terminal

14170060

It is connected to the ground terminal at the cabinet top and ground bar in the equipment room.

Grounding terminal of the chassis

25 mm2 (4 AWG)–M6 single-hole OT naked crimping terminal

14170147

It is connect to the cabinet.

25 mm2 (4 AWG)–M6 double-hole OT naked crimping terminal

14170119

It is connected to the ground terminal.

Installing Ground Cable

NOTE:
  • If the NE40E-X8 is near the ground bar in the equipment room, connect the ground cable of the NE40E-X8 directly to the ground bar. If the NE40E-X8 is distant from the bar, connect the ground cable to the ground point on the cabinet.
  • In this section, connecting the device ground cable directly to the ground bar is used as an example.
  • All ground terminals must be secured using captive screws, as shown below:



    1. Washer 2. Elastomer 3. Screw

  • The grounding cables must connect to a common bonding network.

Perform the following procedures to install ground cables.

  1. Attach temporary labels to both ends of each ground cable.
  2. Route the ground cable for the cabinet along the cable ladder and connect it to the ground terminal on the top of the cabinet, as shown in 1 in Figure 11-10. Connect the other end of the ground cable to the ground bar in the equipment room.
  3. Install the ground cable for the NE40E-X8, as shown in 2 in Figure 11-10. Connect the other end of the ground cable to the ground bar in the equipment room.
  4. Attach permanent labels 20 mm (0.79 in.) from both ends of each ground cable, as shown in 3 and 4 in Figure 11-10.
    Figure 11-10 Installing ground cables

Translation
Download
Updated: 2019-01-03

Document ID: EDOC1100055059

Views: 39313

Downloads: 283

Average rating:
This Document Applies to these Products
Related Documents
Related Version
Share
Previous Next